Datasheet
Web: www.spscap.com
Tel: +86-755-89486800
Fax: +86-10-61272268
Email: info@spscap.com
SCE SHZ DATASHEET
Supreme Power
1 / 2
ISO 9001; ISO/TS 16949:2009
Supreme Power Solutions Co., Ltd.
SPSCAP All Rights reserved, design, specifications
are subjected to change without notice. Version: V2017-2
Features
Threaded connection
Low ESR
Over 1000,000 duty cycles
Applications
Pitching control system of Wind Turbine Generator
UPS and backup power supply
Electronic tools and police flash lights
Dimensions
Cap/F
Dimension/ mm
L1
L2
360
62.2
67
400
62.2
67
600
96.2
101
Specifications
Items
Characteristics
Operating Voltage
2.7 VDC
Surge Voltage
2.85 VDC
Operating Temperature Range
-40℃ to 65℃
Capacitance Tolerance
-10% to +20% (25℃)
Temperature Performance(-40℃ to 65℃)
ΔC ≤ 5% of initial measured value@ 25℃
ESR ≤ 150% of specified value
Life (1500 hours @ 65℃, 2.7 VDC)
ΔC ≤ 20% of initial measured value
ESR ≤ 200% of specified value
Cycle life (1,000,000 cycles between V
R
and 1/2 V
R
)
ΔC ≤ 20% of initial measured value
ESR ≤ 200% of specified value
Φ35.3Max
L1±0.3
L2±0.3
2×M5 deep7
Φ35.5Max
3±0.15
12.7±0.1
Φ 8±0.1
Vent
Max torque 4N·m