MSDS

Shandong Dongyue Chem. CO., LTD.
4 / 8
Self-contained breathing apparatus (SCBA) is
required if containers rupture and contents are
released under fire conditions. Water runoff should
be contained and neutralized prior to release.
SECTION 6. ACCIDENTAL RELEASE MEASURES
NOTE: Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL)
sections before proceeding with cleanup. Use
appropriate PERSONAL PROTECTIVE
EQUIPMENT during clean-up.
Safeguards (Personnel) : Evacuate personnel to safe areas. Ventilate area,
especially low or enclosed places where heavy
vapours might collect.
Spill Cleanup : Evaporates.
Accidental Release Measures : Avoid open flames and high temperatures.
Self-contained breathing apparatus (SCBA) is
required if a large release occurs.
SECTION 7. HANDLING AND STORAGE
Handling (Personnel) : Use sufficient ventilation to keep employee exposure
below recommended limits. For personal protection
see section 8. Handle in accordance with good
industrial hygiene and safety practice.
Handling (Physical Aspects) : The product should not be mixed with air for leak
testing or used with air for any other purpose above
atmospheric pressure. Contact with chlorine or other
strong oxidizing agents should also be avoided.
Storage : Valve protection caps and valve outlet threaded
plugs must remain in place unless container is
secured with valve outlet pipedto use point. Do not
drag, slide or roll cylinders. Use a suitable hand
truck for cylinder movement. Use a pressure
reducing regulator when connecting cylinder to
lower pressure (>3000 psig) piping or systems.
Never attempt to lift cylinder by its cap. Use a check
valve or trap in the discharge line to prevent
hazardous back flow into the cylinder. Cylinders
should be stored upright and firmly secured to
prevent falling or being knocked over. Separate full
containers from empty containers. Keep at
temperature not exceeding 52°C. Do not store near
combustible materials. Avoid area where salt or other
corrosive materials are present.