Use and Care Manual
11
TECHNICAL SPECIFICATIONS
MODEL SD-52PE SD-72PE
Moisture Removal ** 50 pints per day 70 pints per day
Application Area 350 sq. ft. 550 sq. ft.
Power Supply 1Ph, 115V / 60Hz
Current 4.7A 6.9A
Power Consumption 520W 720W
Energy Factor (EEV) 1.85 L/kWh
Starting Current 22A 33A
Working Environment
41 ~ 95°F
35% to 85% RH
Water Tank Capacity 7L
Air Flow (High//Low) 320/280 m3/h
Noise Level (High) 58.5 dB(A)
Dimension 15.39(W) x 10.98(D) x 23.23(H) in.
Packaging 16.61 x 12.68 x 24.21 in.
Net/Gross Weight 36.38/38.58 lbs 39.68/41.89 lbs
** Capacity will vary according to actual room ambient temperature and humidity conditions.
TROUBLE SHOOTING
BEFORE COTACTING THE MANUFACTURER, PLEASE CHECK THE FOLLOWING
POSSIBILITIES.
PROBLEM CHECK
Unit fails to start
• Power is OFF or power cord is unplugged/not securely fitted.
• Set humidity has been reached; water bucket is not placed properly or full
• Check power to the outlet, fuse/circuit breaker box
Performance decreased
• Blocked air filter or air inlet/outlet are blocked
• Room windows and doors are open
• Not enough time allowed to remove the moisture
• Humidity setting may be set too high
• Ambient temperature is too cold, below 41°F
Unit is noisy
• Unstable setting of unit or floor surface is not level
• Blocked filter
Frost appears on coils
• This is normal. The dehumidifier has Auto-Defrost feature
Water on floor
• Hose connection for continuous drainage or pump drainage is loose
• Intend to use the bucket for water collection, but the drain plug is removed.
ES, AS, P2, EC, EB and
E3 appears in display
• Refer to error codes on page 5.
Unit is not collecting as
much water during the
winter months
• When temperature is low, absolute humidity level will drop as well, even
when relative humidity is at the same percentage. There is less water
vapor in the air when temperature is low
Difficulty inserting the
continuous drain tube
• Soak the plastic white connector in hot water for a few minutes will soften
the plastic and make it easier to connect.
The Pump indicator light
blinks
• Clean the pump filter
• Check the pump hose is not kinked or blocked
• Empty the water in the bucket
If you still cannot solve the problem after trying the above, unplug unit and contact Sunpentown Int’l Inc.