Installation Guide

Installation Preparation
PREPARE ELECTRICAL WIRING
GROUNDING INSTRUCTIONS--Power Cord Models
This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord
having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate
outlet that is installed in an accordance with all local codes and ordinances.
ELECTRICAL CONNECTION
Electrical connection is on the right front of dishwasher.
For cable direct connections the cable must be routed as shown. Cable must extend a minimum of 24” from the rear
wall. For power cord connections, install a 3-prong grounding type receptacle in the sink cabinet rear wall, 6 min.
and 16max. From the opening, 6to 16” above the floor.
Care shall be exercised, when the appliance is
installed or removed, to reduce the likelihood of
damage to the power-supply cord.
4
The edges of the opening specified in 2 shall, if the
partition is wood, be smooth and rounded, or, if the
partition is metal, be covered with an edge protector
provided for this purpose by the manufacturer; and
3
There shall be an opening through the partition
between the compartments specified in 1 that is
large enough for the attachment plug to pass through.
The longest dimension of the opening shall not be
more than 38mm.
2
The power-supply socket for the appliance shall be
installed in a cabinet or on a wall adjacent to the
undercounter space in which the appliance is to be
installed.
1
White
10"
6"
24"
from Wall
3"
from
Cabinet
Alternate
Receptacle
Location
Ground
Black
1-1/2" Dia. Hole (Max.)
10"
6"
Receptacle
Location
Area
This dishwasher is designed for operation on an adequately wired individual 120VAC, 60HZ, and connected to an
individual, properly grounded branch circuit, protected by a 15 or 20 amp circuit breaker or time-delay fuse.
If the electric supply does not meet the above specifications, contact a licensed electrician before proceeding.
Your dishwasher circuit should not be used for any other appliance while the dishwasher is in operation. The
dishwasher requires the full capacity of the circuit.
If the wall socket used for the dishwasher is controlled by a switch, turn off the switch before installation.
3
ELECTRICAL REQUIREMENT
FOR PERSONAL SAFETY:
Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter
plug with this appliance.
WARNING!
WARNING!
Improper connection of the equipment-grounding conductor can result in a risk of electric shock .Check with a qualified
electrician or service representative if you are in doubt wether the appliance is properly grounded. Do you modify the plug
provided with the appliance; If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
GROUNDING INSTRUCTIONS--Cable Direct
This appliance must be connected to a grounded metal, permanent wiring system ,or an equipment-grounding
conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on
appliance.
Figure 8