05-03-457 A029-OK.PDF Instruction Manual P O RTA B L E Air Conditioner Model No. WA-1400E Model No. WA-1410E Model No. WA-1400H Model No. WA-1410H ʳ It is important that you read these instructions before using your new purchase and we strongly recommend that you keep them in a safe place for future reference.
05-03-457 A029-OK.PDF TABLE OF CONTENTS THANK YOU ENERGY SAVING TIPS………..……………………………………………….. 2 SPECIFICATIONS..……………………………………………………………….3 BEFORE USE……….……………………………………………………………. 4 PARTS………..…………………………………………………………………….5 INSTALLATION.…………………………………………………………………...6 MOUNTING OF THE EXHAUST PIPE ………………………………………... 7 INSTALLATION OF THE CARBON FILTER…………………………………...8 OPERATION ………………………………………………………………………9 NOTICE.…………………………………………………………………………..12 DRAINAGE……………………………………………………………………….
05-03-457 A029-OK.PDF THANK YOU Thank you for choosing the portable air conditioner from SPTUSA, a leading brand in indoor air treatment. We would like you to enjoy the many benefits this unit offers, so please take the time to read this manual carefully and take full advantage of the many advanced features that your SPTUSA Air Conditioner offers you.
05-03-457 A029-OK.PDF SPECIFICATION Cooling capacity WA-1400E WA-1410E 14000 BTU/hr Heating capacity - Model no. Power/Ampere consumption for cooling* Power/Ampere consumption for heating* Air volume (max. speed) Humidity removal capacity Recommended room size Power supply Compressor Refrigerant Refrigerant load* Fan speed Timer Working temperature Thermostat Exhaust pipe Net Weight Dimension WA-1400H WA-1410H 14000 BTU/hr 14000 BTU/hr 1250W/ 11.0A 1250W/ 11.0A - 1250W/ 11.
05-03-457 A029-OK.PDF BEFORE USE Important! Transport the unit in an upright position only or leave in upright position for at least 2 hours before use. Keep at least 20 inches away from the wall. (Figure 1 & 4) Always place the unit on an even surface. Make sure the unit is connected to a correctly grounded power supply (refer to the rating label located at the back of the unit). FIG.
05-03-457 A029-OK.PDF PARTS Front Back FIG. 5 1. Control Panel 2. Air outlet 3. Carrying handle 4. Caster FIG.6 5. Air filter 6. Air inlet 7. Exhaust air outlet 8. Water stopper / drainage point 9. Cord storage Accessories 10. Inward adaptor - for insertion over hose and connect to back of the air conditioner. 11. Round connector - for insertion over hose and into foam strip (or into hole in the wall/window). 12. Exhaust hose: Length: 14”-60” Diameter: 4.75” 13.
05-03-457 A029-OK.PDF INSTALLATION EXHAUST PIPE INSTALLATION The unit is a portable air conditioner that may be moved from room to room. 1. Using the foam strips / Window installation Used to cover the window gap and can be cut to size if necessary. Foam strips K LQF a • • • • FIG.8 Attach hose to unit and insert other end through the foam strip. Attach Round Connector (part 11) by turning clock-wise. Insert strip into window gap as shown and slide window across so that foam is held securely.
05-03-457 A029-OK.PDF Mounting of the exhaust pipe • Use only the hose provided. Attach hose to back of unit by connecting the adaptor. • Avoid kinks and sharp bends in the exhaust hose as this will cause expelled moist air to build up and the unit will overheat and shut FIG.11 down. Fig 11 & 12 shows correct position • The hose may be extended from 12 inches to 59 inches but for maximum efficiency use the shortest length possible. FIG.12 FIG.
05-03-457 A029-OK.PDF Installing the Carbon Filter 1. Remove the filter frame from the unit. 2. Unclip and remove one side of the frame. 3. Remove the active carbon filter from its plastic bag. 4. Insert the active carbon filter into the filter frame. 5. Replace the other half of the frame. 6. Re-insert the filter frame inside the unit. 7. It is recommended to replace the carbon filter every 3 to 6 months. Replacement Filter: FIG.
05-03-457 A029-OK.PDF OPERATION Control panel $872 21 2)) &22/ )$1 +($7 /R 0, +, 7,0(5 57 : ) 7 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Automatic mode indicator Cooling mode indicator Fan mode indicator Heating mode indicator (for cool & heat models only).
05-03-457 A029-OK.PDF Auto Mode When this mode is selected, the unit is preset to the following temperature settings and unit will only start to: Cool when room temperature is higher than 75°F Heat when room temperature is lower than 68°F (WA-1400H &WA-1410H models only) If room temperature is between 68°F and 75°F, unit will stay in Fan mode. Again, when in Auto Mode, the temperature settings cannot be changed.
05-03-457 A029-OK.PDF Setting ventilation speed 1. Press SPEED button to choose the desired ventilation speed: High, Medium or Low. The indicator respective speed will light on at the same time. 2. If the unit is in AUTO mode, it will choose the ventilation speed automatically according to the ambient temperature (the related indicators will light on), at this time, this button is invalid. Setting timer 1.
05-03-457 A029-OK.PDF Regulating air flow direction Adjust louver on the air vent horizontally to control air flow direction. FIG. 19 NOTICE ! The compressor will start approximately 3 minutes after the compressor is turned off (this will help prolong the life of the compressor). After switching the unit off, please wait at least 3 minutes before turning the unit back on. The cooling system will switch off if the room temperature is 1ºF lower than set.
05-03-457 A029-OK.PDF .DRAINAGE During the process of cooling or heating, some water will be extracted from the air. Most of this water is used to cool the cooling coils and make the unit run more efficiently. This is a feature not found in most other portable air conditioners. If the unit is operated in a VERY HUMID environment, water will start to collect in the built-in water reservoir. When the water tank becomes full, the compressor and fan will stop. The water full indicator (W.F.
05-03-457 A029-OK.PDF Original drain Extended drain tube (OD: 3/4in) NOTE The drain tube must be at or below the outlet level. Water Full (full water) indicator will not FIG.23 function in this mode of drainage. If you wish to extend the water tube, please connect with another tube (outside diameter 3/4"). Special caution for heating function! While using the heating function, please note: 1. Install the exhaust hose to exhaust cool air outdoors.
05-03-457 A029-OK.PDF .MAINTENANCE Always unplug the unit before cleaning and maintenance. Cleaning the Housing Use a soft, damp cloth to wipe the body clean. Never use strong chemicals, oil-based products, detergents, chemically treated cloths or other cleaning solutions. These could possibly damage the cabinet. Cleaning the Filter First remove the black active carbon filter from the frame, tap lightly to remove loose dust and dirt.
05-03-457 A029-OK.PDF .TROUBLE SHOOTING The unit doesn’t run or only runs in fan mode Is the machine plugged in? Is the main power supply on? Is room temperature within working temp range? Is unit set in Auto mode? Select Cool or The unit seems to do little The unit seems to do nothing The room is not cold enough Too noisy The compressor doesn’t run Heat mode and set to proper temperature. Is there direct sunlight? Please draw curtains and blinds.
05-03-457 A029-OK.PDF .DEFECTIVE NOTICE If this product is defective or not working properly Please DO NOT return to your retail store Please contact us directly with any Service or Technical Assistance Contact us toll free at: 1-800-330-0388 REPLACEMENT FILTERS: To purchase Replacement Filters for this unit, contact SPTUSA at 1-800-330-0388 and request model number WA-1400F.
05-03-457 A029-OK.PDF Portable Air Conditioner / Heater Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired or replaced free of charge. This guarantee is subject to the following terms: SPTUSA, must be notified of the fault. Proof of purchase must be presented to SPTUSA’s nominated representative. The warranty will be void if the product is modified, misused or repaired by an unauthorized person.
05-03-457 A029-OK.PDF SAFETY POWER SUPPLY CORD: This Portable Air Conditioner is provided with a Leakage Current Detection and Interruption circuit (LCDI) built into the plug of the power supply cord. This device provides protection to reduce the risk of fire due to arcing faults in the power-supply cord. Each time before using the Portable Air Conditioner, follow the “plug Testing Instructions” given below to ensure that the LCDI circuit is functioning properly. PLUG TESTING INSTRUCTIONS: 1.