PORTABLE AIR CONDITIONER Owner’s Manual & Installation Manual WA-S7000E: 10,000Btu/h (cooling only) IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
Table of Contents Safety Precautions Safety Precautions . ...................................................................................................................03 Installation Instructions Preparation.................................................................................................................................11 Design Notice.............................................................................................................................
Safety Precautions Safety Safety Precautions Read Safety Precautions Before Operation and Installation To prevent death or injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause death, harm or damage. WARNING This symbol indicates the possibility of personnel injury or loss of life. CAUTION This symbol indicates the possibility of property damage or serious consequences.
Safety Precautions • In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning. • Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately if it occurs. • All wiring must be performed strictly in accordance with the wiring diagram located inside of the unit.
Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant) 1. Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific information on the type, the amount and the CO2 equivalent in tonnes of the fluorinated greenhouse gas(select models only), please refer to the relevant label on the unit itself. 2. Installation, service, maintenance and repair of this unit must be performed by a certified technician. 3.
Safety Precautions For R32 refrigerant models: Appliance shall be installed, operated and stored in a room with a floor area larger than 43.06 sq.ft . Appliance shall not be installed in an unvertilated space, if that space is smaller than 43.06 sq.ft . Compliance with national gas regulations shall be observed. Keep ventilation openings clear of obstruction. The appliance shall be stored so as to prevent mechanical damage from occurring.
Safety Precautions Caution: Risk of fire/ flammable materials (Required for R32/R290 units only) Explanation of symbols displayed on the unit(For the unit adopts R32/R290 Refrigerant only): This symbol shows that this appliance used a flammable refrigerant. If the refrigerant WARNING is leaked and exposed to an external ignition source, there is a risk of fire. CAUTION This symbol shows that the operation manual should be read carefully.
Safety Precautions The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
Page 9 Safety Precautions being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
Safety Precautions oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place.
Installation Instructions Preparation NOTE: All the illustrations in the manual are for explanation purpose only. Your machine may be slightly different. The actual shape shall prevail. The unit can be controlled by the unit control panel alone or with the remote controller. This manual does not include Remote Controller Operations, see the <> packed with the unit for details.
Ambient Temperature Range For Unit Operating MODE Temperature Range MODE Temperature Range Cool 17-35°C (62-95°F) Heat(pump heat mode) 5-30°C (41-86°F)(select models only) Dry 13-35°C (55-95°F) Heat(electrical heat mode) ≥ 30°C (86°F)(select models only) The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. For COOL,HEAT(heat pump type) or AUTO mode (select models only) must be installed exhaust hose.
What should I look for first when purchasing a portable air conditioner? number means more cooling power for a larger room. (Be sure you are comparing only newer models to each other- older models may appear to have a higher capacity, but are actually the same). Be sure to “size up” if your portable air conditioner will be placed in a very sunny room, in a kitchen, or in a room with high ceilings. After you’ve found the right cooling capacity or your room, you can look at other features.
Other Regions Name of Accessories Qty. Shape Name of Accessories Qty.
Step Two: Install the Exhaust hose assembly to the unit Push the Exhaust hose into the air outlet opening of the unit along the arrow direction. Installation Instructions Bolt MODEL A Window slider A Step Three: Preparing the Adjustable Window Slider 1. Choose the window sliders according the size of your window. Sometimes, it needs to be cut short to meet the window size, please take extra care to cut it properly.
Installation NOTE: Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following two installation methods. Type 1: Hung Window or Sliding Window Installation(Select models only) Installation Instructions Foam seal B (Adhesive type-shorter) Foam seal B (Adhesive type-shorter) Or Foam seal A (Adhesive type) Foam seal A (Adhesive type) 1. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown.
Or Installation Instructions 5. Insert the window slider adaptor into the hole of the window slider. Type 2: Wall Installation(Select models only ) 1. Cut a 125mm (4.9inch) hole into the wall for the Wall Exhaust Adaptor B. 2. Secure the Wall Exhaust Adaptor B to the wall using the four Anchors and Screws provided in the kit. 3. Connect the Exhaust Hose Assembly(with Wall Exhaust Adaptor A) to the Wall Exhaust Adaptor B.
Operating Instructions Control Panel Features NOTE: The following control panels are for explanation purpose only. The control panel of the unit you purchased may be slightly different according to the models. Your machine may not contain some indicators or buttons. The actual shape shall prevail. FRESH(Press 3s) Auto FRESH(Press 3s) Operating Instructions Heat FRESH FRESH FRESH(Press 3s) MODE button Selects the appropriate operating mode.
DRY operation · Press the "MODE" button until the "DRY" indicator light comes on. · The fan speed or the temperature cannot be adjusted. The fan motor operates at LOW speed. NOTE:Keep windows and doors closed for the best dehumidifying effect. Do not put the duct to window.
thermostat allowing for the precise temperature control at its location. To activate the Follow Me/Temp Sensing feature, point the remote control towards the unit and press the Follow Me/Temp Sensing button. The remote control will send this signal to the air conditioner until press the Follow Me/Temp Sensing button again. If the unit does not receive the Follow Me/Temp Sensing signal during any 7 minutes interval, the unit will exit the Follow Me/Temp Sensing mode.
Maintenance Safety Precautions · · · · Always unplug the unit before cleaning or servicing. DO NOT use flammable liquids or chemicals to clean the unit. DO NOT wash the unit under running water. Doing so causes electrical danger. DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.
Troubleshooting Tips Problem Possible Causes P1 Protection Code Unit does not turn on when pressing In COOL mode: room ON/OFF button temperature is lower than the set temperature Solution The Water Collection Tray is full. Turn off the unit, drain the water from the Water Collection Tray and restart the unit. Reset the temperature Contact the manufacturer or its service agents or a similar qualified person for service.
REMOTE CONTROLLER IMPORTANT NOTE: Thank you for purchasing our air conditioner. Please read this manual carefully before operating your new air conditioning unit. Make sure to save this manual for future reference.
Remote Controller Specifications Battery Type AAA Battery x 2 Signal Receiving Range 8m Environment -5°C~60°C(23°F~140°F) Quick Start Guide 2 1 3 AUTO COOL DRY HEAT FAN FIT BATTERIES 6 SELECT MODE 5 SELECT TEMPERATURE 4 AUTO LOW MED HIGH AU CO TO OL DR HE Y AT SET TEMPE RATUR E FA N HIG ME H LO D W Mo de On /Of f Sw Fan ing My Sle Mo de Fol low Se ep Me LE r lf Cle D er ise Tim Ion Tur bo an PRESS POWER BUTTON POINT REMOTE TOWARD UNIT SELECT FAN SPEED NOT SUR
Handling the Remote Controller Inserting and Replacing Batteries Your air conditioning unit may come with two batteries(some units). Put the batteries in the remote control before use. 1. Slide the back cover from the remote control downward, exposing the battery compartment. 2. Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment. 3. Slide the battery cover back into place.
Buttons and Functions Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual. 1 TEMP : Decreases temperate in 1°F increments. Min. temperature is 62°F. 2 TEMP : Increases temperate in 1°F increments. Max. temperature is 86°F. 3 ON/OFF: Turns the unit on or off.
Remote Screen Indicators Information are displayed when the remote controller is power up. Mode display DRY COOL AUTO HEAT AUTO FAN COOL HIGH Displayed when data transmitted. DRY MED Displayed when remote controller is ON.
How to Use Basic Functions ATTENTION Before operation, please ensure the unit is plugged in and power is available. AUTO Mode Select AUTO mode Set your desired temperature Turn on the air conditioner MODE ON/OFF NOTE: 1. In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT function based on the set temperature. 2. In AUTO mode, fan speed can not be set.
Setting the TIMER TIMER ON/OFF - Set the amount of time after which the unit will automatically turn on/off. TIMER ON setting Press TIMER ON button to initiate the ON time sequence. Press Temp. up or down button for for multiple times to set the desired time to turn on the unit. Point remote to unit and wait 1sec, the TIMER ON will be activated.
How to Use Advanced Functions SLEEP function SLEEP The SLEEP function is used to decrease energy use while you sleep (and don t need the same temperature settings to stay comfortable). This function can only be activated via remote control. The sleep function is not available in Fan or Dry mode.Please refer to the OWNER’S MANUAL for more details.
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.
SUNPENTOWN Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired free of charge. This guarantee is subject to the following terms: Sunpentown must be notified of the fault. Proof of purchase must be presented to Sunpentown’s nominated representative. The warranty will be void if the product if modified, misused or repaired by an unauthorized person.