Troubleshooting
If the switch panel is not operating as expected, watch the Transmit LED and press one of the buttons to
see if it comes on. If the LED does not come on, check the power source. Replace the CR2032 battery and try
operating the switch panel again. If the Transmit LED still does not turn on when pressing a button after
troubleshooting the power source, the switch panel has failed and needs to be replaced.
If the switch panel does not operate as expected, but the Transmit LED does come on when pressing the
button there is likely a problem with the receiver device. If the transmit LED works but the icons on the receiving
device do not change color when pressing a button, SSP17 2-Position switch panel need to be paired again to the
device and repeat the procedure. If after re-pairing the SSP17 2-Position switch panel to the receiver, it still does
not function correctly, the SSP17 2-Position switch panel is considered faulty and need to be replaced. If the icons
on the receiving device turn red or alternate between red and green, the signal strength is not strong enough and
the SSP17 2-Position switch panel is considered faulty and need to be replaced. Refer to the document of the
receiver device being used for more detailed instructions on troubleshooting and pairing procedures.