Brochure

Pendant Stations
Type SKYP General Information
14
07/2013 © 2013 Schneider Electric
All Rights Reserved
Type SKYP General Information
This line of pendant stations consists of polymeric enclosures (2–10 units),
push button units (1–5 speed), and laminated legend plates. All enclosures
have an extra single-unit space near the top that permits the installation of a
toggle switch, a Type SK operator or pilot light, or a warning label (see
Table 29 on page 15). All enclosures come standard with a stainless-steel
hanger bracket and internal strain-relief post. The enclosures are yellow
with a threaded opening in the top. The complete line is UL Listed and CSA
certified, with NEMA Type environmental ratings 1, 2, 3, 3R, 4, 4X, and 12
(NEMA 4 only with legend plates installed). To ensure Type 4X and 13
integrity, use only Type 4X and 13 operators or closing plates.
Type SKYP Specifications
There is a 10% charge for assembly. To place a custom pendant order,
use the worksheet on 18 as a guide. Orders must be placed through the
Product Selector in Quote to Cash.
Table 24: Type SKYP Specifications
Electrical
Ratings
Types SKRU2–SKRU5: AC = NEMA / UL B300; DC = NEMA / UL P600
Types SKRU1, 10, 11: AC = NEMA / UL A600: DC = NEMA / UL P600
Enclosure Type UL Type 1, 2, 3, 3R, 4, 4X, 12, and 13
Operating
Temperature
-30 C to +60 C (-13 F to +140 F)
Storage
Temperature
-40 C to +70 C (-40 F to +158 F)
Housing Material Polycarbonate
Cable Entry 1/2” NPT
Approvals
File E78403
CCN NKCR
File LR 25490
Class 3211 03
Lifetime
Enclosure
Warranty
®
Table 25: Electrical Contact Ratings (Types SKRU2 through SKRU5)
AC—NEMA / UL Type B300
Volts
[1]
1
OSHA Regulation, Section 1910.170 Overhead and Gantry Cranes, limits the voltage at pendant push buttons to 150 Vac or 300 Vdc.
Inductive, 35% Power Factor Resistive, 75% Power Factor
Make Break
Continuous Carrying Amperes
Make, Break, and
Continuous Carrying Amperes
AVAAVA
120 30 3600 3 360 5 5
240 15 3600 1.5 360 5 5
Table 26: Electrical Contact Ratings (Types SKRU1, 10, and 11)
AC—NEMA / UL Type A600 DC—Standard Duty, NEMA / UL Type P600
Volts
[1]
1
OSHA Regulation, Section 1910.170 Overhead and Gantry Cranes, limits the voltage at pendant push buttons to 150 Vac or 300 Vdc.
Inductive, 35% Power Factor
Resistive,
75% Power Factor
Volts
Inductive and Resistive
Make
Amperes
Break
Amperes
Continuous
Carrying Amperes
Make, Break, and Continuous
Carrying Amperes
Make and
Break Amperes
Continuous
Carrying
Amperes
120 60 6 10 10 120 1.1 10
240 30 3 10 10 240 0.55 10
480 15 1.5 10 10
600 12 1.2 10 10 600 0.2 10