Energy Guide

© 2019 Schneider Electric
All Rights Reserved
3-27
www.se.com/us
600 Volt Double Throw Safety Switches Double Throw Safety Switches
Class 3110 / Refer to Catalog 3100CT1602
Double Throw Safety Switches
Table 3.47: 600 V Double Throw Safety Switches
System Amperes
Current
Series
NEMA
Type 1
NEMA
Type 3R
NEMA Type
4,4X,5
304 Stainless
Steel
NEMA Type 12
Gasketed
Horsepower Ratings [11][12]
240 Vac 480 Vac 600 Vac
Vdc [13]
Std Max Std Max Std Max
250 600
Cat. No. Cat. No. Cat. No. Cat. No.
[14] [14]
Fusible 3P, 600 Vac—600 Vdc
Line
Line
Load
30 F DT361 DT361RB
 5
[15]
15
[15]
 7.5 20  5
15
[16]
60 F DT362 DT362RB
15
[17]
30
[17]
15 50
30
[18]
100 F DT363 DT363RB
25
[19]
60
[19]
30 75
50
[20]
Non-Fusible 3P, 600 Vac—600 Vdc
[13]
[21]
[14]
[21]
[13]
[21]
[14]
[21]
[13]
[21]
[21]
Line
Line
Load
30 F DTU361 DTU361RB  5 10 7.5 20 10 30  5 15
60 F DTU362 DTU362RB DTU362DS
DTU362AWK[22]
10
20[23]
25
50
[24]
30
60
[25]
10 30
100 F DTU363 DTU363RB DTU363DS
DTU363AWK[22]
20
40[26]
40
75[26]
40
100
[26]
20 50
200 E
82344 [27] 82344RB [27]
82344DS [27]
[28]
H82344 [27]
15 [29]
400 A DTU365 DTU365R DTU365DS DTU365AWK 125 250 350 50
600 A
DTU366[30] DTU366R[30]
DTU366AWK[30]
125 250 350 50
Non-Fusible 4P, 600 Vac—600 Vdc
Line
Line
Load
60 F
DTU462[31]
Use NEMA
Type 12
DTU462DS [31]
DTU462AWK[22]
[31]
20 20 40 50 50 60 10 30
100 F
DTU463 [31] DTU463DS [31]
DTU463AWK [22]
[31]
30 40 50 75 50 100 20 50
200 E
82444[30] 82444R[30] 82444DS[30]
H82444 [22] [31]
[32] [30]
400 A
DTU465[30] DTU465R[30]
125 250 350 50
600 A
DTU466 [30]
DTU466R
[30]
125 250 350 50
Non-Fusible 6P, 600 Vac—600 Vdc
Line
Line
Load
60 F
DTU662AWK [22]
[31]
20 50 60 10 30
100 F
DTU663AWK [22]
[31]
40 75 100 20 50
240 V Double Throw: page 3-26
Accessories: page 3-28
Application Data: page 3-30
Dimensions, 30–100 A (Series F): page 3-32
Dimensions, 30, 200–600 A (Series E, T4, A): page 3-33
3
SAFETY SWITCHES
[11] The starting current of motors of more than standard horsepower may require the use of fuses with appropriate time delay characteristics.
[12] Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses. (Non-fusible switches have max rating unless noted.)
[13] Use outer switching poles.
[14] If used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded conductors.See data bulletin 2700DB0202 for additional information.
[15] 480 Vac 1 Phase HP = 3 Std, 7.5 Max
[16] 10 Std, 15 Max
[17] 480 Vac 1 Phase HP = 5 Std, 20 Max
[18] 25 Std, 30 Max
[19] 480 Vac 1 Phase HP = 10 Std, 30 Max
[20] 40 Std, 50 Max
[21] Maximum HP
[22] Complete rating on switch is NEMA Type 3R, 5 or 12. For 3R applications, remove drain screw from bottom endwall.
[23] Maximum HP is 15 for corner grounded delta systems.
[24] Maximum HP is 30 for corner grounded delta systems.
[25] Use 75
o
C #4 Cu or #2 Al conductors only on DTU362 and DTU362RB.
[26] Use 75
o
C #1 Cu conductors only.
[27] 480 Vac, 250 Vdc maximum
[28] Not UL Listed.
[29] Standard Hp rating.
[30] 250 Vdc maximum.
[31] Not suitable for use as service equipment.
[32] 480 Vac, 250 Vdc maximum.
9/13/2019