Commercial Pressure and Float Switches for Power Circuits
Electromechanical Pressure Switches, Class 9013 Types F and G
38
03/2011
TM
Type G, 2-Pole, 2 N.C. Contacts
Degree of Protection IP20, NEMA Type 1, 3R, 7, and 9
Flange Style
Adjustable range of setting point
Contacts open on rising pressure
Fluid Connections 1/4" NPSF internal 1/4" NPSF internal 1/8" NPSF internal 1/4" NPSF internal 3/8" NPSF internal 1/8" NPSF internal
Catalog Numbers
NEMA Type 1, IP20 9013GMG2 9013GSG1 9013GSG2 9013GSG3
NEMA Type 3R
[1]
1
Must be mounted in vertical position to maintain enclosure rating.
9013GSB2
NEMA Type 7, 9 —————9013GSR1
Fluids / Pressure
Controls
Water or air Water or air Water or air Water or air Water or air Water or air
Pressure Range
Cut-out psig (bar) 10–35 (0.7–2.4) 20–80 (1.4–5.5) 20–80 (1.4–5.5) 20–80 (1.4–5.5) 20–80 (1.4–5.5) 20–80 (1.4–5.5)
Cut-in psig (bar) 5.5–30.5 (0.4–2.1) 5–60 (0.4–4.2) 5–60 (0.4–4.2) 5–60 (0.4–4.2) 5–60 (0.4–4.2) 5–60 (0.4–4.2)
Weight, lb (kg) 2 (0.91) 2 (0.91) 2 (0.91) 2 (0.91) 2 (0.91) 8 (3.62)
Supplemental Specifications (not shown under General Specifications)
Differential psig (bar) 4–8 (0.3–0.6) 15–30 (1.0–2.1) 15–30 (1.0–2.1) 15–30 (1.0–2.1) 15–30 (1.0–2.1) 20–40 (1.4–2.8)
Maximum Allowable
Pressure psig (bar)
35 (2.4) 80 (5.5) 80 (5.5) 80 (5.5) 80 (5.5) 80 (5.5)
Cable Entry
3 knockouts for
1/2 in. conduit
3 knockouts for
1/2 in. conduit
3 knockouts for
1/2 in. conduit
3 knockouts for
1/2 in. conduit
3 knockouts for
1/2 in. conduit
2 conduit entries
3/4"-14 NTP
Pressure Switch Style Diaphragm
Ordering information Pressure codes
1. Select the catalog number from the table above.
2. Select the pressure code and add the code
designation to the end of the catalog number.
Ensure that the pressure code falls within the
limits of the device as shown in the device listings.
3. If special features are desired, add the
appropriate Form letter to the catalog number
after the pressure code. Arrange the Form letters
in alphabetical sequence when ordering more
than one special feature.
4. Add the packaging code at the end of the
sequence, after the Forms. (For example, to order
a standard pack of 10 devices, specify
9013GHG2J99RZC10.) If no packaging code is
indicated, the devices will be shipped individually
packaged.
To order a standard pack of 10 devices per box
C10 (available on GHB, GHG, GSB, and GSG)
see page 39 for Form C10.
NOTE: Existence of a code does not imply that the code is available for any
or all devices.
Settings (psi) Code Settings (psi) Code
20–40 J20 110–150 J56
30–50 J21 120–150 J57
40–20 J23 125–150 J58
40–60 J24 125–175 J60
60–80 J25 130–175 J61
70–90 J26 140–170 J66
70–100 J28 140–175 J62
75–100 J29 145–175 J63
80–100 J30 150–120 J64
90–120 J31 150–175 J67
100–80 J51 215–250 J65
100–125 J53 Specify pressure settings J99
110–125 J54