Table of Contents Load Centers Load Center EZ Selector - Selection Assistance QO™ Miniature Circuit Breakers QO™ Miniature Circuit Breakers QO Plug-On Circuit Breakers QO Accessories QO™ Load Centers Value Packs QO Load Center Accessories Homeline Load Center Accessories Qwik-Grip Load Center Accessories Surge Protective Devices QO/Homeline Load Center Dimensions Indoor Enclosure Dimensions and Knockout Information Rainproof, Dimensions, Knockouts and Bolt-on Hubs Combination Service Entrance Devices
EZ Selector - Selection Assistance 1 Load Center EZ Selector - Selection Assistance Class 1140 www.se.com/us QO™ and Homeline™ Load Center EZ Selector - Selection Assistance LOAD CENTERS EZ Selector Steps to select a load center. 1. Select product type: • Homeline™ 1 inch format (HOM) • QO™ 3/4 inch format with plug-on neutral (QO) (P) • QO™ 3/4 inch format (QO) 2. Select enclosure type: indoor or outdoor (RB = rainproof) 3. Select single phase (1) or three phase (3) 4.
QO Plug-On Circuit Breakers QO™ Miniature Circuit Breakers Class 730, 731, 733 / Refer to Catalog: 0730CT9801 www.se.com/us Square D brand QO miniature circuit breakers are plug-on products for use in QO load centers, NQOD and NQ panelboards, NQOD and NQ OEM interiors or Speed-D™ switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD and NQ panelboards or interiors.
QO™ Miniature Circuit Breakers QO Plug-On Circuit Breakers 1 Class 730, 731, 733 / Refer to Catalog: 0730CT9801 www.se.com/us QO/QOB Ring Terminal Table 1.2: QO/QOB Ring Terminal—Factory-Installed Only LOAD CENTERS Ampere Rating 10–30 A 35–60 A 35–50 A 70–110 A 60–100 A Poles 1, 2, 3 1,2 3 2 3 Suffix 5237 5238 5273 Wire Sizes for QO/QOB Circuit Breakers Table 1.
QO Plug-On Circuit Breakers QO™ Miniature Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 www.se.com/us Table 1.
QO™ Miniature Circuit Breakers QO Plug-On Circuit Breakers 1 Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 www.se.com/us QO-EPD/EPE Circuit Breakers QO-EPD/EPE circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 mA level (EPD) or 100 mA level (EPE). They are not designed to protect people from electrical shock. LOAD CENTERS Table 1.
QO Plug-On Circuit Breakers QO™ Miniature Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 www.se.com/us High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications. Table 1.
QO™ Miniature Circuit Breakers QO Accessories 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us Accessories for QO/QOB Circuit Breakers Table 1.15: Accessories for use with QO and QOB Miniature Circuit Breakers Description Cat. No.
QO™ Load Centers QO Indoor Load Centers, 1Ø Class 736, 1130 / Refer to Catalog 1100CT0501 Plug-on Neutral Load Center Main Lugs, Convertible Mains (1Ø3W—120/240 Vac Indoor—UL Listed) QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plugon Neutral connection on every unit. Table 1.
QO™ Load Centers QO Indoor Load Centers, 1Ø 1 Class 736, 1130 / Refer to Catalog 1100CT0501 www.se.com/us Field-Installed Main Circuit Breaker Kits, 1Ø Table 1.
QO™ Load Centers QO Indoor Load Centers, 1Ø Class 736, 1130 / Refer to Catalog 1100CT0501 www.se.com/us The Square D QO plug-on neutral load centers with Qwik-Grip simplify rough-in by eliminating the need to remove knockouts, install wire connectors, and blindly pull wire into the load center. A quick bend of the wire using the wire bend guide on the Qwik-Grip insert and the wire slides into the slot.
QO™ Load Centers QO Load Centers, Rainproof, 1Ø 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us Plug–on Neutral Load Center Main Lugs, Convertible Mains (1Ø3W—120/240 Vac Rainproof—UL Listed) LOAD CENTERS QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plugon Neutral connection on every unit. Table 1.24: Convertible Main Lugs Plug-on Neutral Load Center (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers) Max.
QO™ Load Centers Backup Power Solutions, 1Ø Class 1130 / Refer to Catalog 1100CT0501 Table 1.26: Backup Power Solutions Mains Rating (A) I N D O O R R A I N P R O O F Spaces Max. Single Pole Circuits [24] Max.
QO™ Load Centers QO Special Constructions, 1Ø 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us QO Standard Load Center Main Lugs and Main Breaker, Fixed Mains (1Ø3W—120/240 Vac Special Applications—UL Listed) LOAD CENTERS Table 1.28: Low Amperage Fixed Main Lugs Indoor Load Centers (Accepts Only QO Plug-on Circuit Breakers - Not compatible with QO Plug-on Neutral Circuit Breakers) Max. Max.
QO™ Load Centers QO Special Constructions, 1Ø Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us Mains Rating R A I N P R O O F Spaces Max. Single Pole Circuits [47] Max.
QO™ Load Centers QO Special Constructions, 1Ø 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us QO Riser Panels (1Ø3W—120/240 Vac Special Applications—UL Listed) Table 1.33: Riser Panels for Offset Interior for Wide Gutter—30 A Maximum Branch Circuit Breaker on Left Side of Interior [55] , [56] (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers) LOAD CENTERS Main Wire Size AWG/ Equipment Ground Max. Single Max.
QO™ Load Centers QO Indoor, Rainproof Load Centers, 3Ø Class 1130 / Refer to Catalog 1100CT0501 QO Standard Load Center Main Lugs and Main Breaker (3Ø4W—208Y/120 Vac, 3Ø4W—240/120 Vac Delta and 3Ø3W—240 Vac Delta—Indoor and Rainproof—UL Listed) Table 1.36: Main Lugs and Main Breaker Load Centers (Accepts Only QO Plug-on Circuit Breakers - Not compatible with QO Plug-on Neutral Circuit Breakers) Cu Equipment Ground Bar Kit (Order Separately) Box No.
Homeline™ Miniature Circuit Breakers Homeline Plug-On Circuit Breakers 1 Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Homeline Standard Plug-On Circuit Breakers LOAD CENTERS The Square D Homeline circuit breakers are in a 1 in. wide format for 1-pole circuit breakers. They are designed to plug into Homeline load centers. Table 1.
Homeline Plug-On Circuit Breakers Homeline™ Miniature Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Homeline Combination Arc Fault and Ground Fault Circuit Interrupters (Dual Function)— Provide overload and short circuit protection, plus arc fault and ground fault protection in a single device in accordance with the NEC, UL1699 and UL943. Table 1.
Homeline Accessories Homeline™ Miniature Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 1 www.se.com/us Homeline Circuit Breaker Wire Sizes Table 1.
Homeline™ Load Centers Homeline Load Centers, Indoor, 1Ø Class 1170 / Refer to Catalog 1100CT0501 Table 1.49: Fixed Main Lugs Load Centers (Accepts Only HOM Plug-on Circuit Breakers - Not compatible with HOM Plug-on Neutral Circuit Breakers) Main Wire Size Max. Max.
Homeline™ Load Centers Homeline Load Centers, Indoor, 1Ø 1 Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Field-Installed Main Circuit Breaker Kits, 1Ø Table 1.
Homeline™ Load Centers Homeline Load Centers, Indoor, 1Ø Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Table 1.
Homeline™ Load Centers Homeline Load Centers, Rainproof, 1Ø 1 Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us HOM Standard Load Center Main Lugs, Fixed Mains (1Ø3W—120/240 Vac Rainproof—UL Listed LOAD CENTERS Table 1.57: Fixed Main Lugs Load Centers (Accepts Only HOM Plug-on Circuit Breakers - Not compatible with HOM Plug-on Neutral Circuit Breakers) Mains Rating Spaces Max. Single Pole Circuits [25] Max. Tandem Circuit Breakers Load Center Box, Interior and Cover Cat. No.
Value Packs QO/Homeline Load Center Value Packs and Accessories Class 1130, 1170 / Refer to Catalog 1100CT0501 www.se.com/us I N D O O R Spaces Max.
1 QO/Homeline Load Center Value Packs and Accessories QO Load Center Accessories Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us QO Load Center Accessories Table 1.
Homeline Load Center Accessories QO/Homeline Load Center Value Packs and Accessories Class 1130 / Refer to Catalog 1100CT0501 www.se.
Indoor Enclosure Dimensions and Knockout Information QO/Homeline Load Center Dimensions 1 Class 1130, 1170 / Refer to Catalog 1100CT0501 www.se.com/us Indoor Enclosure Dimensions and Knockout Information Table 1.67: Enclosure Dimensions LOAD CENTERS Box No. 1 2 3 4 5 6 7 8 9 10 11 12 W in. 3.81 4.81 4.81 8.88 14.25 14.25 14.25 14.25 14.25 14.25 14.25 14.25 Dimensions H in. mm 6.72 171 9.30 236 9.30 236 12.57 319 14.92 379 17.92 455 20.92 531 26.04 661 29.86 758 33.78 858 37.98 965 39.
Indoor Enclosure Dimensions and Knockout Information www.se.com/us QO/Homeline Load Center Dimensions Class 1130, 1170 / Refer to Catalog 1100CT0501 Table 1.69: Indoor Knockout Information and Enclosure Dimensions for Qwik Grip Loadcenters in. 14.25 14.25 14.25 14.25 14.25 14.25 7Q 8Q 9Q 10Q 11Q 12Q H mm 362 362 362 362 362 362 D in. 20.92 26.04 29.86 33.78 37.98 39.37 mm 531 661 758 858 965 1000 in. 3.75 3.75 3.75 3.75 3.75 3.
QO/Homeline Load Center Dimensions 1 Rainproof, Dimensions, Knockouts and Bolt-on Hubs Class 1130, 1170 / Refer to Catalog 1100CT0501 www.se.com/us Enclosure Dimensions and Knockout Information Table 1.70: Enclosure Dimensions Dimensions W LOAD CENTERS Box No. in. 6.52 4.88 8.88 14.75 14.75 14.75 14.75 14.75 14.75 4.56 6.92 7.56 9.62 6.92 14.75 8.88 8.55 8.
Catalog Number Logic for CSEDs Combination Service Entrance Devices Class 4119, 4120 www.se.
Combination Service Entrance Devices Rainproof, Meter Mains 1 Class 4119, 4120 www.se.
Rainproof, Meter Mains Combination Service Entrance Devices Class 4119, 4120 www.se.
Combination Service Entrance Devices 1 Rainproof, All-In-Ones, 100 to 225 A Maximum Class 4120 www.se.com/us Meter Mains and All-In-Ones (100 to 225 A Maximum) UL Listed, suitable only for use as service equipment Meets EUSERC standards • • Service disconnect(s) are supplied factory-installed, except where noted Semiflush-reverse design available, supplied with load center (indoor access) • • Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires.
Rainproof, Meter Mains and All-In-Ones, 300–400 A Combination Service Entrance Devices Class 4119, 4120 www.se.com/us • • • UL Listed, suitable only for use as service equipment Meets EUSERC standards where indicated. Service disconnects are supplied factory-installed, except where noted Supplied with 100% branch neutrals; all unused terminals may be used for equipment grounding wires Meets Federal Specification W-P-115c as Type 1, Class 2 Cat. No. 2P Circuits (Max.) Ampere Rating Max.
Combination Service Entrance Devices Circuit Breakers for CSEDs Class 4119, 4120 1 www.se.com/us Table 1.
Accessories and Hubs for CSEDs Combination Service Entrance Devices Class 4119, 4120 www.se.com/us Accessories and Hubs for CSEDs Cat. No. RCGK2 QCGK3 PK2SCPV 5J MMHB 29007 2920910001 29008W ARP00026 MMLRK SU2X6TRIM SCBRLLOCK 1 Description Generator Kit: Interlocks main service disconnect and generator circuit breaker (order separately).
Combination Service Entrance Devices Dimensions for CSEDs Class 4119, 4120 1 www.se.com/us Dimensions for CSEDs Table 1.82: Knockouts 14.97 28.28 “A” Hub 380 718 C,D,F 7.14 7.50 191 181 Drip Hood Semi-Flush End Wall “A” Hub “B” Hub 21/2" Max “A” Hub 4.60 4.60 4.56 117 117 7.50 116 13.46 497 13.82 Blank End Wall 191 19.58 28.25 342 351 10.70 7.44 12.80 8.00 164 272 189 718 6.44 203 18.23 325 463 20.79 528 A,B C,D,E,F 41.
Rainproof, Meter Mains and All-In-Ones, 150 to 200 A Maximum RC/QC Solar Ready CSEDs Class 4120 www.se.com/us • • • • • • Service disconnect(s) are supplied factory-installed, except where noted Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires All devices have a 3" KO in the bottom endwall Provisions for Field Installed CTs All Devices Solar Ready kit SR69064A fits All Devices Below, order from Table 1.
Homeline Solar Ready PoN CSEDs 1 Rainproof, Meter Mains and All-In-Ones, 125 to 225 A Maximum Class 4120 www.se.
Wiser Energy™ Wiser Energy™ Smart Home Class 4120 www.se.com/us Wiser Energy from Square D is an integral part of any smart home. With Wiser Energy, you can give your home a voice. It helps you keep tabs on your home by notifying you when devices are on or off in the home, and monitors home energy usage in real time, for a safer and more efficient home.
Enclosed Devices Class 1130 / Refer to Catalog 1100CT0501 1 www.se.com/us 1Ø3W—120/240 Vac—240 Vac—UL Listed Table 1.89: Enclosed Molded Case Switch, Switch Included, Does NOT provide overcurrent protection LOAD CENTERS Ampere Rating General Purpose Rainproof 240 Vac 60 A [2] [3] QO260NATS QO200TR QO200TRNM QO260NATR Box. No. [1] 2, 9R [4] 1NM 1R 120/240 Vac 100 A [5] QO2000NS QO2000NRB 13, 10R Service Table 1.
Enclosed Devices Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us Table 1.94: QOM2 Enclosures and QOM2 Circuit Breakers Service QOM22225NF/S Type 3R Rainproof Box No. [14] Ampere Rating QOM22225NRB 22, 16R 100 A 125 A 150 A 175 A 200 A 225 A 1 2P 240 Vac Maximum 22 k AIR Cat. No.[15] QOM2100VH QOM2125VH QOM2150VH QOM2175VH QOM2200VH QOM2225VH Cat. No. LOAD CENTERS QOM2 Circuit Breaker (Order Separately) [12] Enclosure Only [11] Type 1 General Purpose [13] Cat. No.
Servicepak™ Power Outlet Panels 1 Class 1140 www.se.com/us Power Outlet Panels for Construction Sites T LOAD CENTERS T T 1C T T T T 2C T • • • • • • • 3C T T T Provide temporary power at construction sites. Each receptacle protected by QO-GFI circuit breaker in compliance with NEC® requirements. Each enclosure is rainproof. 10 kA short circuit current rating. UL Listed as suitable for use as temporary site service equipment. Provided with neutral bonding provisions.