Brochure

7-30
© 2019 Schneider Electric
All Rights Reserved
PowerPactâ„¢ Molded Case Circuit Breakers B-Frame Circuit Breakers
www.se.com/us
Class 0613
PowerPact B-Frame Molded Case Circuit Breakers (125 A)
B-Frame
Thermal-Magnetic Trip Unit
With EverLink Lug
Technology
PowerPact B-frame circuit breakers provides economical thermal-magnetic circuit
protection in a compact size.
•
Fixed 15-125 A thermal-magnetic protection up to 600Y/347 Vac and 250 Vdc
•
1- to 4-pole unit mount construction; 1- to 3-pole I-Line construction
•
UL listed interrupting ratings from 18 kA to 65 kA at 480 Vac
•
EverLink lugs, a cable connection method that helps maintain low resistance
connections
•
UL, CSA, NOM, IEC, CCC certified and CE marked for global acceptance
Table 7.47: PowerPact B-Frame 125 A Thermal-Magnetic Circuit Breakers (600Y/347 Vac) with EverLink Lugs
Cur-
rent
Rating
@
40
o
C
Interrupting Rating
D G J K
1 Pole
347 Vac
125 Vdc
2 Pole
600Y/347
Vac
250 Vdc
3 Pole
600Y/347
Vac
250 Vdc
4 Pole
600Y/347
Vac
250 Vdc
1 Pole
347 Vac
125 Vdc
2 Pole
600Y/347
Vac
250 Vdc
3 Pole
600Y/347
Vac
250 Vdc
4 Pole
600Y/347
Vac
250 Vdc
1 Pole
347 Vac
125 Vdc
2 Pole
600Y/347
Vac
250 Vdc
3 Pole
600Y/347
Vac
250 Vdc
4 Pole
600Y/347
Vac
250 Vdc
1 Pole
347 Vac
2 Pole
600Y/347
Vac
15 A BDL16015 BDL26015 BDL36015 BDL46015 BGL16015 BGL26015 BGL36015 BGL46015 BJL16015 BJL26015 BJL36015 BJL46015 BKL16015 BKL26015
20 A BDL16020 BDL26020 BDL36020 BDL46020 BGL16020 BGL26020 BGL36020 BGL46020 BJL16020 BJL26020 BJL36020 BJL46020 BKL16020 BKL26020
25 A BDL16025 BDL26025 BDL36025 BDL46025 BGL16025 BGL26025 BGL36025 BGL46025 BJL16025 BJL26025 BJL36025 BJL46025 BKL16025 BKL26025
30 A BDL16030 BDL26030 BDL36030 BDL46030 BGL16030 BGL26030 BGL36030 BGL46030 BJL16030 BJL26030 BJL36030 BJL46030 BKL16030 BKL26030
35 A BDL16035 BDL26035 BDL36035 BDL46035 BGL16035 BGL26035 BGL36035 BGL46035 BJL16035 BJL26035 BJL36035 BJL46035 — —
40 A BDL16040 BDL26040 BDL36040 BDL46040 BGL16040 BGL26040 BGL36040 BGL46040 BJL16040 BJL26040 BJL36040 BJL46040 — —
45 A BDL16045 BDL16045 BDL36045 BDL46045 BGL16045 BGL26045 BGL36045 BGL46045 BJL16045 BJL26045 BJL36045 BJL46045 — —
50 A BDL16050 BDL26050 BDL36050 BDL46050 BGL16050 BGL26050 BGL36050 BGL46050 BJL16050 BJL26050 BJL36050 BJL46050 — —
60 A BDL16060 BDL26060 BDL36060 BDL46060 BGL16060 BGL26060 BGL36060 BGL46060 BJL16060 BJL26060 BJL36060 BJL46060 — —
70 A BDL16070 BDL26070 BDL36070 BDL46070 BGL16070 BGL26070 BGL36070 BGL46070 BJL16070 BJL26070 BJL36070 BJL46070 — —
80 A BDL16080 BDL26080 BDL36080 BDL46080 BGL16080 BGL26080 BGL36080 BGL46080 BJL16080 BJL26080 BJL36080 BJL46080 — —
90 A BDL16090 BDL26090 BDL36090 BDL46090 BGL16090 BGL26090 BGL36090 BGL46090 BJL16090 BJL26090 BJL36090 BJL46090 — —
100 A BDL16100 BDL26100 BDL36100 BDL46100 BGL16100 BGL26100 BGL36100 BGL46100 BJL16100 BJL26100 BJL36100 BJL46100 — —
110 A BDL16110 BDL26110 BDL36110 BDL46110 BGL16110 BGL26110 BGL36110 BGL46110 BJL16110 BJL26110 BJL36110 BJL46110 — —
125 A BDL16125 BDL26125 BDL36125 BDL46125 BGL16125 BGL26125 BGL36125 BGL46125 BJL16125 BJL26125 BJL36125 BJL46125 — —
Table 7.48: B-Frame Termination Options
Termination Letter
A = I-Line (See Section 9, Panelboards) B D L 3 6 1 0 0
For factory-installed
termination, place
termination letter in
the third block of the
circuit breaker catalog
number.
F = No Lugs (includes terminal nut kit on both
ends)
L =EverLink Lugs both ends
M = Lugs ON end Terminal Nut Kit OFF end
P = Lugs OFF end Terminal Nut Kit ON end
Table 7.49: B-Frame Interrupting Ratings
Voltage
Interrupting Rating
D G J K
240 Vac 25 kA 65 kA 100 kA 100 kA
480Y/277 Vac 18 kA 35 kA 65 kA 65 kA
480 Vac 18 kA 35 kA 65 kA 65 kA
600Y/347 Vac 14 kA 18 kA 25 kA 65 kA
125 Vdc 10 kA 20 kA 50 kA —
250 Vdc 10 kA 20 kA 50 kA —
Table 7.50: B-Frame Lug Options
Lug Option Suffix
No Suffix = EverLink Lugs both ends B D L 3 6 1 0 0 LU
For factory-installed
lug option, place suffix
after the amperage in
the circuit breaker
catalog number.
LU = EverLink Lug with Control Wire
Terminal ON end; EverLink Lug OFF end
LV = EverLink Lug ON end; EverLink Lug
with Control Wire Terminal OFF end
LW = EverLink Lug with Control Wire
Terminal both ends
LC = Copper Mechanical Lugs both ends
LH = Aluminum Mechanical Lugs both ends
Table 7.51: PowerPact B-Frame 125 A Magnetic Trip Values
Current Rating @
40
o
C
Fixed AC Magnetic Trip
Hold
Trip
15 A 400 A 600 A
20 A 400 A 600 A
25 A 480 A 720 A
30 A 480 A 720 A
35 A 480 A 720 A
40 A 480 A 720 A
45 A 480 A 720 A
50 A 480 A 720 A
60 A 640 A 960 A
70 A 800 A 1200 A
80 A 800 A 1200 A
90 A 1000 A 1500 A
100 A 1000 A 1500 A
110 A 1000 A 1500 A
125 A 1000 A 1500 A
Accessories see page 7-49
Optional Lugs see page 7-54
Dimensions see page 7-81
7
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
9/13/2019