Miniature Circuit Breakers Selection Information
Class 500, 600
Multi 9, EDB Miniature Circuit Breakers
Multi 9™ Circuit Breakers and
Supplementary Protectors
EDB Circuit Breakers
Circuit
Breaker
Type
Plug-on
— — — — —
Bolt-on — — EDB EGB EJB
Unit Mount
UL 489
C60
BP
UL1077
C60
SP
[25]
C60H-DC — — —
Number of Poles 1 2 3 1 2
3,4
1 2 1
2, 3
1
2, 3
1
2, 3
Current Range (A)
0.5–63 0.5–63 0.5–63 0.5–63 1–63 1–63 0.5–63 0.5–63 15–70 15–125 15–70 15–125 15–70 15–125
Interrupting Ratings
UL/CSA
Rating
(kA RMS)
(50/60 Hz)
120 Vac
14 [26] 14 [26] 14 [26] 14 [27] 14 [27] 14 [27]
— — 25 25 65 65 100 100
120/240 Vac
14 [26] 14 [26] 14 [26] 14 [27] 14 [27] 14 [27]
— — 18 25 35 65 65 100
240 Vac [28] 14 [26] 14 [26] 14 [26] 14 [27] 14 [27] 14 [27]
— — 18 25 35 65 65 100
277 Vac — — —
10 [29] 10 [29] 10 [29]
— — 18 18 35 35 65 65
480Y/277 Vac
10 [30] 10 [31] 10 [31]
—
10 [29] 10 [29]
— — — 18 — 35 — 65
DC Ratings
48 Vdc — — — — 10 — 5 5 — — — — — —
60 Vdc 10 10 — 20 — — 5 5 — — — — — —
65 Vdc — — — — — — 5 5 — — — — — —
125 Vdc — 10 — — — — 5 5 — — — — — —
250 Vdc — — — — — — 5 5 — — — — — —
500 Vdc — — — — — — —
5 [32]
— — — — — —
IEC 60947-2
(50/60 Hz)
Icu
240 Vac 10 20 20 10 20 20 — — 20 — — — — —
415 Vac — 10 10 — 5 5 — — 10 — — — — —
Special Ratings
CCC X X X X X X X X — — — — — —
Fed. Specs W-C-375B/GEN
X X X — — — — — X X X X X X
Other Standard IEC HACR
Accessories and Modifications
Shunt Trip
X X X X X X X X
X [33] X [33] X [33] X [33] X [33] X [33]
Undervoltage Trip
X X X X X X X X — — — — — —
Auxiliary Switches
X X X X X X X X
X [33] X [33] X [33] X [33] X [33] X [33]
Alarm Switch X X X X X X X X
X [33] X [33] X [33] X [33] X [33] X [33]
Handle Operators
X X X X X X X X — — — — — —
Handle Padlock Attachment X X X X X X X X X X X X X X
Trip System Type
Thermal-magnetic
X X X X X X X X X X X X X X
Molded Case Switch — — — — — — — — — — — — — —
Dimensions (1P Unit Mount)
Dimensions
(1P Unit Mount)
in. (mm)
Height 4.05 (103) 3.19 (81) 3.19 (81) 5.66 (144)
Width
0.71 (18) 0.71 (18) 0.71 (18) 1.42 (36) 0.98 (25)
Depth 2.76 (70) 2.76 (70) 2.56 (65) 4.05 (103)
Pages page 7-23
See Section 9
NOTE: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted.
7
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
[25] C60 are recognized components per UL 1077.
[26] 14 kA up to 35 A, 10 kA from 40 to 63 A.
[27] 14 kA up to 32 A, 10 kA from 40 to 63 A.
[28] For information regarding 3Ø corner grounded systems see the Supplemental Digest, Section 3.
[29] 10 kA up to 32 A, 5 kA from 40 to 63 A.
[30] Up to 35 A.
[31] 10 kA up to 35 A.
[32] 2 poles must be wired in series for 500 Vdc.
[33] Factory-installed option only.