Brochure
7-54
© 2019 Schneider Electric
All Rights Reserved
PowerPact™ Circuit Breaker Accessories
Mechanical Lugs
www.se.com/us
Class 612 / Refer to Catalog 0612CT0101
Mechanical Lugs
Table 7.103: Mechanical Lug Kits for B-Frame Circuit Breakers [17]
Description
Circuit Breaker Application
Ampere Rating
Number of Wires
Per Lug and Wire Range
Factory-Installed
Cat. Suffix
Field-
Installable
Cat. No.
Qty Per
Kit
Standard
Ampere Rating Optional
Al Lugs for Use with Al
or Cu Wire
BD BG BJ 15-125 A (1) 14-2/0 AWG Al or Cu
LH LV426966 2
BD BG BJ 15-125 A (1) 14-2/0 AWG Al or Cu
LH LV426967 3
Cu Lugs for Use with
Cu Wire Only
BD BG BJ 15-125 A (1) 14-1/0 AWG Cu
LC LV426964 2
BD BG BJ 15-125 A (1) 14-1/0 AWG Cu
LC LV426965 3
EverLink Lug
BD BG BJ (1P) 15 - 125 A (1) 14-3/0 AWG Cu
— — —
BD BG BJ (2P)
15 - 125 A
(1) 14-3/0 AWG Cu
— — —
BD BG BJ (3P)
15 - 125 A
(1) 14-3/0 AWG Cu
— — —
BD BG BJ (4P)
15 - 125 A
(1) 14-3/0 AWG Cu
— — —
EverLink Lug with
Control Wire Terminal
15 - 125 A
BD BG BJ (2P) (1) 14-3/0 AWG Cu LU, LV, or LW [18]
LV426973 1
15 - 125 A
BD BG BJ (3P) (1) 14-3/0 AWG Cu LU, LV, or LW [18]
LV426974 1
15 - 125 A
BD BG BJ (4P) (1) 14-3/0 AWG Cu LU, LV, or LW [18]
LV426975 1
Table 7.104: Mechanical Lug Kits for H- and J-Frame Circuit Breakers [17]
Description
Circuit Breaker Application
Ampere Rating
Number of Wires
Per Lug and Wire Range
Kit Cat. No.
Qty Per
Kit
Standard
Ampere Rating Optional
Al Lugs for Use with
Al or Cu Wire
HD, HG, HJ, HL
15–150 A
(1) 14–3/0 AWG Al or Cu
AL150HD 3
JD, JG, JJ, JL
150–175 A
(1) 4-4/0 AWG Al or Cu
AL175JD 3
JD, JG, JJ, JL
200–250 A
JD,JG,JJ,JL
150–175 A
(1) 3/0–350 kcmil Al or Cu
AL250JD 3
Cu Lugs for Use with
Cu Wire Only
HD,HG,HJ,HL
15–150 A
(1) 14–2/0 AWG Cu
CU150HD 3
JD,JG,JJ,JL
150–250 A
(1) 1/0–300 kcmil Cu
CU250JD 3
Control Wire Terminal for H-frame lug kit
S37423 2
Control Wire Terminal for J-frame lug kit
S37424 2
AL250JD AL400L6IK3 AL600LS52K3
J-Frame Lug L-Frame Lug
Table 7.105: Mechanical Lug Kits for L-Frame Circuit Breakers [19]
Descrip-
tion
Circuit Breaker Application
Number of Wires
Per Lug and Wire Range
Kit Cat. No.
Qty
Per
Kit
Ampere
Rating
Poles
Unit
Mount
I-Line
Al Lugs for
Use with Al
or Cu Wire
250 3 X X (1) 2 AWG–500 kcmil Al
(1) 2 AWG–600 kcmil Cu
AL400L61K3 3
4 X — AL400L61K4 4
400/600 3 X —
(2) 2/0 AWG–500 kcmil Al or Cu
AL600LS52K3 3
4 X — AL600LS52K4 4
400/600 3 X X
(2) 3/0 AWG–500 kcmil Al or Cu
AL600LF52K3 3
Cu Lugs for
Use with
Cu Wire
Only
250 3 X X
(1) 2 AWG–600 kcmil Cu
CU400L61K3 3
4 X — CU400L61K4 4
400/600 3 X —
(2) 2/0 AWG–500 kcmil Cu
CU600LS52K3 3
4 X — CU600LS52K4 4
400/600 3 X X
(2) 3/0 AWG–500 kcmil Cu
CU600LF52K3 3
AL800M23K
AL800P6K
M- and P-Frame Lugs
(800 A and below)
AL800P6K AL1200P6KU
AL1200P25K
P-Frame Lugs (Above 800 A)
Table 7.106: Mechanical Lug Kits for M-, P- and R-Frame Circuit Breakers [20]
Descrip-
tion
Circuit Breaker Application
Wires per Lug
and Wire Range
Cat. No.
Lugs
Per
Kit
Standard
Rating Optional Rating
Al Lugs
for AL or
Cu Wire
M-Frame,
P-Frame
800 A — 800 A
(3) 3/0 AWG-500 kcmil
AL800M23K 3
AL800M23K4 4
1200 A
MG, MJ, PG,
PJ, PK, PL
800 A
(4) 3/0 AWG-500 kcmil AL1200P24K [21]
1
—
MG, MJ, PG,
PJ, PK, PL
800 A
(2) 3/0 AWG-600 kcmil
AL800P6K [21]
3
AL800P6K4 [21]
4
—
MG, MJ, PG,
PJ, PK, PL
800 A
(2) 3/0 AWG-750 kcmil
750 kcmil: compact AL
only
AL800P7K [21]
3
AL800P7K4 [21]
4
P-Frame
1200 A
PG, PJ, PK,
PL
800 A
(4) 3/0 AWG-500 kcmil
AL1200P25K [22]
3
AL1200P25K4 [22]
4
—
PG, PJ, PK,
PL
800–
1200 A
(3) 350-600 kcmil
AL1200P6KU [22]
3
AL1200P6KU4 [22]
4
PG,PJ,PL
—
PG, PJ, PK,
PL
1200 A
(3) 3/0 AWG-750 kcmil
750 kcmil: compact AL
only
AL1200P7KU [22]
3
AL1200P7KU4 [22]
4
R-Frame
1200 A I-Line —
(4) 3/0 AWG-600 kcmil
AL1200R53K 1
2500 A Unit Mount —
(1) 3/0 AWG-750 kcmil AL2500RK [23]
2
Cu Lugs
for Cu
Wire
Only[24]
M-Frame,
P-Frame
— PJ
100–
150 A
(1) 1-1/0 AWG CU250P1K [25]
3
800 A
MG, MJ, PG,
PJ, PK, PL
—
(3) 3/0 AWG-500 kcmil
CU800M23K 3
CU800M23K4 4
1200 A
MG, MJ, PG,
PJ, PK, PL
800–
1200 A
(4) 3/0 AWG-500 kcmil CU1200P24K [21]
1
P-Frame 1200 A
PG, PJ, PK,
PL
800–
1200 A
(4) 3/0 AWG-500 kcmil
CU1200P25K [22]
3
CU1200P25K4 4
R-Frame 1200 A I-Line —
(4) 3/0 AWG-500 kcmil
CU1200R53K 1
7
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
[17] For terminal nuts/bus bar connections see page 7-57.
[18] LU = ON end only, LV = OFF end only, LW = BOTH ends
[19] Lug kits for Legacy L-frame circuit breakers can be found in Supplemental Digest Section 11 (i.e. LA, LH circuit breakers).
[20] For lug with a tapped hole for control wire, add a “T” before the “K” in the catalog number (for example, AL800P6TK).
[21] Does not fit onto ON end of unit-mount P-frame circuit breakers.
[22] For unit-mount circuit breaker only.
[23] All unit-mount R-frame circuit breakers require terminal pads for mounting lugs of any type. See page 7-57.
[24] Not available with tapped hole for control wire.
[25] This lug can only be used on low amp PJ frame breakers where the Instantaneous setting must not be turned OFF. The cables must be laced with rope per lug instructions.
9/13/2019