Brochure
© 2019 Schneider Electric
All Rights Reserved
7-57
www.se.com/us
Terminal Nuts, Terminal Pads, Terminal
Shields and Accessories
PowerPact™ Circuit Breaker Accessories
Class 612 / Refer to Catalog 0612CT0101
Terminal Accessories
H-Frame Lug with
Terminal Nut Insert
Control Wire Terminal for
J-Frame Terminal Nut
Terminal Nut Insert
RLTB Terminal Pad Kit
Table 7.110: Terminal Nuts for Bus Bar Connection of B-, H- and J-Frame Circuit
Breakers
Description
Frame
Tap
Cat. No.
Qty Per
Kit
B-Frame Terminal Nut Insert-Metric
BD/BG/BJ (2P)
M6 LV426962 2
B-Frame Terminal Nut Insert-Metric
BD/BG/BJ (3P)
M6 LV426963 3
H-Frame Terminal Nut Insert–English
HD/HG/HJ/HL 1/4-20 S37425 2
H-Frame Terminal Nut Insert–English
HD/HG/HJ/HL 1/4-20 S37444 3
H-Frame Terminal Nut Insert–Metric HD/HG/HJ/HL M6 S37426 2
J-Frame Terminal Nut Insert–English
JD/JG/JJ/JL 1/4-20 S37427 2
J-Frame Terminal Nut Insert–English
JD/JG/JJ/JL 1/4-20 S37445 3
J-Frame Terminal Nut Insert–Metric JD/JG/JJ/JL M8 S37428 2
Control Wire Terminal for H-Frame Terminal Nut HD/HG/HJ/HL — S37429 2
Control Wire Terminal for J-Frame Terminal Nut JD/JG/JJ/JL — S37430 2
Table 7.111: Bus Bar Connections Hardware for L-, M-, and P-Frame Circuit
Breakers
Frame
Description
Term. No. Poles Cat. No.
L-Frame Set of 4 terminal screws and washers for one side F 4 S36967
M- and P-Frame
Bus Connector Kit for one pole, one end
— 1 S33928
Table 7.112: Terminal Pad Kits for R-Frame Circuit Breakers
R-Frame
Circuit Breaker
Terminal Pad Kit Field-Installable Kits
Usage
Lugs
per
Phase
3P Kit (One
End Only)
Cat. No.
4P Kit (One
End Only)
Cat. No.
3000 A, 100% Rated [33] Required for cable or bus
9 RL3TB RL3TB4
3000 A, Standard (80% Rated) [34] Required for cable or bus
2500 A, 100% Rated
Required for cable or bus
8 RLTB RLTB4
2500 A, Standard (80% Rated) Required for cable, optional for bus
All Other R-Frame Circuit Breakers
Required for cable, optional for bus
For cable connection to RLTB, use AL2500RK lug. See page 7-55.
H-Frame Short
Lug Shield
J-Frame Short
Lug Shield
Molded Case
w/Mechanical
Lugs
“B” See Table
“B” See Table
Phase barrier or terminal
shield extension past end
of circuit breaker
R-Frame
Phase Barrier
Table 7.113: Terminal Shields and Phase Barriers
Used With
Description
Dimension B
(in.)
Cat. No.
Qty Per
Kit
H- and J-
Frame
Mechanical
Lugs
Short Lug
Shield [35]
Frame Max. Wire Size
H-Frame 60 A 3 AWG 0.50 S37446 1
H-Frame 150 A 3/0 AWG 0.50 S37447 1
J-Frame 350 kcmil 0.24 S37448 1
B-, H- and J-
Frame
Power
Distribution
Connectors
and
Compression
Lugs
Compatible with:
PDC
Compression Lugs
Aluminum
Copper
B-Frame
Long Lug
Shield
PDC3BD2
L-
V426988
LV426986
1.9
LV426911 (2P)
LV426912 (3P)
LV426913 (4P)
1
PDC6BD6
L-
V426989
LV426987
H-Frame
Long Lug
Shield
PDC6HD6 YA060HD CYA060HD
2.24 S37449 1
PDC3HD2 YA150HD CYA150HD
J-Frame
Long Lug
Shield
PDC6JD4 YA150JD CYA150JD
1.68 S37450 1
PDC3JD2
[36]
CYA250J3
L-Frame
3P Short Terminal Shield LTSS3P 1
3P Medium Terminal Shield LTSM3P 1
3P Long Terminal Shield
LTSL3P 1
4P Medium Terminal Shield LTSM4P 1
4P Long Terminal Shield
LTSL4P 1
M-, P-Frame
Phase Barriers
S33646
3
R-Frame S33998
Table 7.114: Miscellaneous H-, J-, and L-Frame Circuit Breaker Accessories
Accessory Description
Field-Installable
Cat. No.
Spare Parts
Bag of screws for accessory cover, L-frame
S432552
1 spare toggle extension, L-frame
32595
Set of 10 identification labels LV429226
7
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
[33] 3000 A 80% and 100% rated RL3TP (3P) and RL3TP4 (4P) ship with 2 kits.
[34] 2500 A 80% and 100% rated RLTB (3P) and RLTB4 (4P) ship with 2 kits.
[35] Short lug shields provide IP20 protection for mechanical lugs and are compatible with control wire terminals.
[36] J-frame terminal shield is not compatible with the YA250J35 compression terminal.
9/13/2019