Selection Information Molded Case Circuit Breakers
www.se.com/us
Class 500, 600, 800
B-, H-, J-Frame Molded Case Circuit Breakers
PowerPact™ 125 A B-Frame PowerPact 150 A H-Frame PowerPact 250 A J-Frame
Electronic Trip Version Electronic Trip Version
Circuit Breaker Type
BD BG BJ BK HD HG HJ HL HR JD JG JJ JL JR
Number of Poles
1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 1, 2 2, 3 2, 3
2, 3 [34] 2, 3 [34]
3
2, 3 [34] 2, 3 [34] 2, 3 [34] 2, 3 [34]
3
Current Range (A)
15–125 15–125 15–125 15–30 15–150 15–150 15–150 15–150 15–150
70–250
[35]
70–250
[35]
70–250
[35]
70–250
[35]
70–250
[35]
Interrupting Ratings
UL/CSA/
NOM AC
Rating
(kA RMS)
(50/60 Hz)
240 Vac 25 65 100 100 25 65 100 125 200 25 65 100 125 200
480Y/277 Vac 18 35 65 65 18 35 65 100 200 18 35 65 100 200
480 Vac 18 35 65 65 18 35 65 100 200 18 35 65 100 200
600Y/347 Vac 14 18 25 65 14 18 25 50 100 14 18 25 50 100
600 Vac 14 18 25 50 100 14 18 25 50 100
UL/CSA/
NOM DC
Ratings
250 Vdc [36]
[37]
10 20 50 20 20 20 20 20 20 20 20
500 Vdc [36]
20 50 20 50
IEC AC
Rating
(kA RMS)
(50/60 Hz)
Icu/lcs [38]
220/240 Vac 25 65 100 100 25 65 100 125 150 25 65 100 125 150
380/415 Vac 18 35 65 65 18 35 65 100 125 18 35 65 100 125
440/480 Vac 18 35 65 65 18 35 65 100 125 18 18 25 50 125
500/525 Vac 14 18 25 25 14 18 25 50 75 14 20 20 20 75
690 Vac 20 20
IEC DC
Ratings
250 Vdc 20 20 20 20
500 Vdc 20 20 20 20
Special Ratings
CCC X X X X X X X X X X X X X X
Fed. Specs W-C-375B/GEN
X X X X X X X X X X X X X X
HACR X X X X X X X X X X X X X X
Connections/Terminations
Unit Mount X X X X X X X X X X X X X X
I-Line™ X X X X X X X X X X X X X X
Rear Connection
X [39] X [39]
X X X X X X X X
Drawout
X [39] X [39]
X X X X X X X X
Optional Lugs
X X X X
X [39] X [39]
X X X X X X X X
Accessories and Modifications
Shunt Trip
X X X X X X X X X X X X X X
Undervoltage Trip
X X X X X X X X X X X X X X
Auxiliary Switches
X X X X X X X X X X X X X X
Alarm Switch X X X X X X X X X X X X X X
Motor Operator
X [39] X [39]
X X X X X X X X
Handle Operators
X X X X
X [39] X [39]
X X X X X X X X
Mechanical Interlocks (3P)
X X X X X X X X X X X X X
Handle Padlock Attachment X X X X
X [39] X [39]
X X X X X X X X
Cylinder Lock (3P)
Optional GF Protection
X X X X X X X X X X
Trip System Type
Thermal-magnetic
X X X X X X X X X X X X X
Instantaneous-only (MCP)
X
X [40] X [40] X [40]
X [40] X [40]
X X
Molded Case Switch
(Automatic)
X X X X X X X X X
Electronic
X [40] X [40] X [40] X [40] X [40] X [40] X [40] X [40] X [40] X [40]
Enclosures (page 7-80page 7-82)
General Purpose (NEMA 1)
X X X X X X X X
Raintight (NEMA 3R)
X X X X X X X X
Dust-tight (NEMA 12)
X X X X X X X X
Watertight (NEMA 4, 4X, 5)
X X X X X X X X
Explosion Proof (NEMA 7, 9)
X [41] X [41]
Dimensions
(3P Unit
Mount)
in. (mm)
Height 5.4 (137) 6.4 (163) 7.5 (191)
Width
3.2 (81) 4.1 (104) 4.1 (104)
Depth 3.5 (89) 3.4 (86) 3.4 (86)
Pages (Unit Mount) / (I-Line) page 7-30 / Section 9 page 7-31 / Section 9 page 7-31 / Section 9
NOTE: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted.
7
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
[34] 2P in a 3P module.
[35] 70–250 A with electronic trip system
[36] Not available with electronic trip units
[37] 1P Available at 125 Vdc
[38] Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest, Section 10.
[39] Not available in HD and HG 2P rating (2P module).
[40] 3P only.
[41] Not UL Listed due to wire bending space.