Product data sheet
Characteristics
HOM4080M200PQCVP
Load center, Homeline, 1 phase, 40 spaces, 80
circuits, 200A convertible main breaker, PoN,
NEMA1, Qwik-grip, value pack
Main
Product or component
type
Load Center value pack
Marketing Trade Name Homeline
Load center type Main breaker
Line Rated Current 200A
Number of spaces 40
Number of circuits 80
Enclosure Rating NEMA 1 indoor
Cover type Combination flush/surface cover
Included Options Circuit breaker 2) 1P 20A 120/240 V AC
Circuit breaker 1) 2P 100A 120/240 V AC main
supply ready assembled
Circuit breaker 1) 2P 30A 120/240 V AC
Load center 1)
Qwik grip assembly kit 1)
Complementary
Short-circuit current 10kA
Number of Tandem Breakers 40
Number of Phases 1 phase
[Ue] rated operational voltage 120/240 V AC
Wire Size AWG 4...250 kcmil aluminium/copper
Enclosure material Welded galvannealed steel
Surface finish Baked enamel Gray
Box number 12Q
Maximum Height 39.37in (1000mm)
Maximum Width 14.25in (362mm)
Maximum Depth 3.74in (95mm)
Environment
Ambient air temperature for operation 23°F (-5°C)
104°F (40°C)
Product certifications UL
Ordering and shipping details
Category 00185 - MISC. HOM LOAD CENTERS
Discount Schedule DE3C
GTIN 00785901613879
Package weight(Lbs) 40.2lb(US) (18.23kg)
Returnability Yes
Country of origin US