Measurement Guide

SUPPLIED
WITH
ACPL CLOSING PLATE
(FOR UNDERGROUND
SERVICE) ORDER TYPE
A-L
HUB SEPARATELY
(FOR OVERHEAD SERVICE)
TOP POSITION
OMITTED
ON
J-GANG
UNIT
TENANT CIRCUIT
BREAKER DOORS
(PADLOCKABLE)
COYER
KNOCKOUT
FOR
-----1-='t__:"'J
USE
WITH
UTILITY
BARREL LOCK (RINGLESS
DEVICES ONLY)
INDIVIDUAL
METER
SOCKET COVERS:
RING
TYPE (INCLUDES
SNAP TYPE ALUMINUM
SEALING RINGS)
OR
RINGLESS STYLE
(SUPPLIED
WITH
COVER
SEALING
LATCHES)
2.76
[70]
7.28
~~~~~~~
D
~J
TO
TOP
OF
MOUNTING
CHANNEL
.09
[2]
n~[i~
DIA~.09
XQ33
SLOT
MOUNTING CHANNEL
DETAIL
FIFTH
JAW
FACTORY
INSTALLED
ON
RINGLESS
DEVICE
NEUTRAL
[3] [8]
RINGLESS
COVER
LATCH
.10
DIA___y=nr
[
3
]
~
___)2..-l.10
0
N
EQUIPMENT
GROUNDING
TERMINAL
.42
DIA
[3]
[11]
SEAL BRACKET
838
f
1.73
[24] + [10]
[44]
MOUNTING
FOOT
X
.40
SLOT
[10]
DIA
KNOCKOUTS
CONDUIT SIZE
HOLE
DIAMETER
SYMBOL
IN
MM
IN
MM
A
.50
13
.88
22
B
.75
19
1.25
32
c
1.00
25
1.38
35
D
1.25
32
1.75
44
E
1.50
39
2.00
51
F
2.00
51
2.50
64
G
2.50
64
3.00
76
H
3.00
76
3.63
92
I
3.50
89
4.13
105
J
4.00
102
4.63
117
INTERRUPTING
SQUARE D
RATING
RMS
CIRCUIT
SYMMETRICAL
CIRCUIT
RATING
AMPERES
AT
BREAKER
AMPERES
120/240
v
CATALOG
MAX
AC
MAXt
DESIGNATION
10,000
QO
125
22,000
QO-VH
125
42,000
QOH
125
ALTERNATE
MECHANICAL
LUGS
WIRE
SIZE
CATALOG
NO
(1)
1/0
600
AWG/KCMIL
OR
MMLK250
(2)
1/0-250
PER
PHASE
(2)
3/0-500
AWG/KCMIL
PER
PHASE
MMLK500
(2)
2-600
AWG/KCMIL
PER
PHASE
MMLK600
DUAL
DIMENSIONS:
INCHES
MILLIMETERS
A-L
HUB
PROVISION
E,F,G,H,I,J
AND SERVICE
GROUND
120/240VAC,
10
3
WIRE
OR
LOAD
LUG
WIRE
NOTES:
A-L
HUB
PROVISION
E,F,G,H
FINISH - UL COMPONENT RECOGNIZED
GRAY
BAKED
POWDER
COAT
PAINT
OVER
CLEANED PHOSPHATIZED STEEL.
UL
LISTED
-
FILE
E-6294.
SUITABLE
ONLY
FOR
USE
AS
SERVICE EQUIPMENT. SUITABLE
FOR
OH/UG
SERVICE.
RING-lYPE
DEVICE
SUPPLIED
WITH
4-JAW
METER
SOCKET, 5TH
JAW
KIT
AVAILABLE
SURFACE MOUNT, CONVERTABLE
TO
SEMI-FLUSH
WITH
FIELD INSTALLED
KIT.
MECHANICAL
LUGS
FACTORY
INSTALLED,
LUG
LANDING
PADS
AVAILABLE.
ORDER
CATALOG
NUMBER MMLK2.
LOAD
PHASE
LUGS
ARE
SUPPLIED
AS
A
PART
OF
THE
CIRCUIT BREAKER (TENANT SERVICE DISCONNECT).
t
THE
METER
CENTER
SHORT
CIRCUIT CURRENT
RATING
IS
EQUAL
TO
THE
LOWEST
SHORT CIRCUIT CURRENT
RATING
GIVEN
IN
THE
TABLE
FOR
ANY
CIRCUIT BREAKER INSTALLED
IN
THE
METER
CENTER.
METER
SOCKET
COVER
208y/240VAC,
10
3
WIRE
(5TH
JAW
REQUIRED)
METER
NO.
OF
NO.
FACTORY
SOCKET
METER
OF
INSTALLED
MAIN
COVER
SOCKETS
JAWS
BYPASS
BUS
RATING
RING
lYPE
3 4 NONE
300
RING
lYPE
4 4 NONE
400
RING
LESS 3 5 NONE
300
RING
LESS 3 5 NONE
300
RING
LESS 4 5 NONE
400
RING
LESS 4 5
HORN
400
MP
METER-PAK
METERING EQUIPMENT
NEMA
lYPE
3R ENCLOSURE
125A
MAXIMUM
TENANT
CIRCUIT BREAKERS
LINE
LUG
WIRE
SIZES
CATALOG
(AWG/KCMIL)
NUMBER
PHASE
AND
NEUTRAL
MP33
125
MP44
125
MPR33-125
(1)
1/0-600
OR
MPH33-125
(2)
1/0-250
MPR44-125
MPH44-125
SIZES (AWG-KCMIL)
NEUTRAL,
PHASE.
SERVICE
GROUND
& EQUIPMENT
GROUNDING
SEE
CIRCUIT
2/0-14
cu.
BREAKER
WIRE
2/0-12
AL
SIZE