- Según los requisitos de demanda de energía y de la capacidad de la fuente de respaldo, el Centro de Energía ofrece tres modos de respaldo, tal como se describe a continuación:
- A high performance, easy to install whole-home Surge Protective Device (SPD) is also factory installed in the Energy Center. Featuring the industry-leading plug-on neutral architecture, this device meets the NEC code requirements and allows for the q...
- En el Centro de Energía también se instala de fábrica un dispositivo de protección contra sobretensiones (DPS) de alto rendimiento y fácil de instalar para toda la casa. Con la arquitectura de neutro enchufable líder en la industria, este dispo...
- Convenience Outlet and GFI MCB (CRN#: SQR442124WH and QO120PGFI)
- Tomacorriente adicional y GFI MCB (CRN#: SQR442124WH y QO120PGFI)
- The Energy Center provides a reliable means to conveniently access electricity energy from the outside of the home. The enclosure features a factory-installed 20 A / 125 V weather resistant receptacle protected by a 20 A ground-fault (GFCI) miniature...
- El Centro de Energía proporciona un medio confiable para acceder cómodamente a la energía eléctrica desde el exterior de la casa. El gabinete cuenta con un receptáculo resistente a la intemperie de 20 A / 125 V instalado de fábrica y protegido ...
- Hold-down Bracket Kit (CRN#: QOCRBGK2EC)
- Kit de soporte de sujeción (CRN#: QOCRBGK2EC)
- For convenience, a QO hold-down bracket kit is provided to meet the requirement of NEC 705.12 (B) (5) required for back feed use during battery backup. This hold-down bracket kit is intended to be associated with the solar inverter back-fed circuit b...
- Para mayor comodidad, se proporciona un kit de soporte de sujeción QO para cumplir con la norma NEC 705.12 (B) (5) requerido para el uso de retroalimentación mientras se utiliza la batería de respaldo. Este kit de soporte de sujeción está diseñ...
- El kit se utiliza para enclavar mecánicamente dos interruptores automáticos QO bipolares adyacentes, un interruptor automático de la acometida con el interruptor automático del generador, 50 A máximo, y para retener el interruptor automático de...
NNZ30993 QOWC60M200PFY Square D™ Energy Center
08/2021 QOWC60M200PFY Centro de Energía Square D™
© 2021 Schneider Electric All Rights Reserved / Reservados todos los derechos 11
Backup Power Modes (cont.) Modos de alimentación de respaldo (cont.)
Advanced Backup Mode cont. Modo de respaldo avanzado (cont.)
8. Install hold-down bracket kit (QOCRBGK2EC) on the
circuit breaker and secure it with the screw. Torque
screw to 20 lb-in (2.25 N•m).
9. Attach interlock (QO2DTI) to the new advanced
backup mode selection dedicated circuit breaker. Hook
tab in the slot at the OFF end of the circuit breaker.
Use a flat blade screwdriver to bend the tab into the
slot at the ON end of the circuit breaker. See Figure 6.
Note: When the non backup sub-main circuit breaker is in
the OFF position, the advanced backup mode selection
circuit breaker will be in the ON position. This combination
enables a whole home backup mode. On the other hand,
when the non backup sub-main circuit breaker is in the
ON position, the advanced backup mode selection circuit
breaker will be in the OFF position. This combination
represents a partial backup mode.
8. Instale el kit de soporte de sujeción (QOCRBGK2EC) en el
interruptor automático y fíjelo con el tornillo. Apriételo a 20 lbs-pulg
(2,25 N•m).
9. Conecte el enclavamiento (QO2DTI) al nuevo interruptor automático
dedicado de selección de modo de respaldo avanzado. Enganche la
lengüeta en la ranura del extremo de Apagado (OFF) del interruptor
automático. Con un destornillador de punta plana doble la lengüeta
en la ranura del extremo de Encendido (ON) del interruptor
automático. (Vea la figura 6.)
Nota: Cuando el interruptor automático secundario sin respaldo está en
la posición OFF, el interruptor automático de selección del modo de
respaldo avanzado estará en la posición ON. Esta combinación habilita
el modo de respaldo para toda la casa. Por otra parte, cuando el
interruptor automático secundario sin respaldo está en la posición ON,
el interruptor automático de selección del modo de respaldo avanzado
estará en la posición OFF. Esta combinación representa el modo de
respaldo parcial.
Figure / Figura 6: Installing Advanced Backup Mode / Instalación del modo de respaldo avanzado
External Backup
Interface /
Interfaz de re-
spaldo externo
IN / OUT /
Entrada
Salida
Top section 110 A sub main circuit breaker /
Interruptor automático secundario de 110 A
de la sección superior
Bottom section 110 A sub main circuit
breaker /
Interruptor automático secundario de
110 A de la sección inferior
Advanced backup mode selection circuit
breaker QO2110 /
Interruptor automático de selección de modo
de respaldo avanzado QO2110
QO2DTI
Hold-down bracket /
Soporte de sujeción
5/16