Rainproof, Meter Mains Combination Service Entrance Devices
Class 4119, 4120
Rainproof Meter Mains
Table 1.81: Rainproof Meter Mains
Ampere Rating
Bypass Type
Service
(Type of Feed)
Short Circuit
Current Rating
Cat. No.
Service Disconnect(s)
Load Center and Branch
Circuit Breakers
(Order separately [1])
Hub Type (Order
separately [2])
Line
Side
Main
Lugs
AWG/
kcmil
(Al/
Cu)
Service
Ground
Lug|
AWG/|
kcmil|
(Al/Cu)
Weight
Each
(Lbs)
and
Pallet
Qty.
2P
Circuits
(Max.)
Type
(Order
separately [3])
Ampere
Rating Max.
Max. Quantity
Ampere
Rating Max.
Spaces
1P
Circuits
Tan-
dems
UL
UL and
EU-
SERC
Ring Type, QO
TM
Surface Mount Only
125 A None OH/UG 10 kA C125RB 1
QOM1-VH
125 A B 4–1/0 8–1/0
15, 54
200 A None
OH/UG 22 kA CM200S 1
QOM2-VH
200 A A 4–250
(2)8–2/0
26, 24
OH/UG
22 kA C2M200S
1
1
QOM2-VH
QO-VH
200 A
 50 A
A 4–250
(2)8–2/0
27, 20
OH/UG 10 kA C4L200S 2
QO
100 A A 4–250
(2)8–2/0
27, 28
Ring Type, Homeline
TM
Surface Mount Only
125 A None OH/UG OH/UG 10 kA SC8L125S 4 HOM
125
A
A 6–2/0 6–2/0
31, 24
200 A None OH/UG OH/UG 10 kA SC12L200S 6 HOM
200 A
[4]
A–L 4–250 8–2/0
40, 10
Semiflush Mount only
125 A None OH/UG OH/UG 10 kA SC8L125F 4 HOM 110 A
A or
B300
6–2/0 6–2/0
37, 20
200 A None
OH [5]/
UG
OH [5]/
UG
10 kA SC12L200F 6 HOM
200 A
[6]
A–L 4–250 8–2/0
47, 10
Surface Mount—Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers
150 A None OH/UG
10 kA
SC816D150C [7] [8]
1
HOM2150 [9]
HOM
150 A
 50 A
8 16 8
100 A
[10]
A or A–L 6–300 8–1/0
48, 18
UG
SU816D150C [7] [8]
1
200 A None UG
10 kA
SC816D200C [7] [8]
1
HOM2200 [9]
200 A
 50 A
8 16 8
100 A
[10]
A or A–L 6–300 8–1/0
48, 18
UG
SU816D200C [7] [8]
1 HOM
Ringless, QO
TM
Surface Mount Only
200 A
None
OH/UG
22 kA
RC200S [11]
1
QOM2-VH
200 A
A 6–350
(2)8–2/0
26, 24
Lever 10 kA
RCM200SL [11] [12]
1
QOM2-VH
200 A A 6–350 8-1/0 60 / 14
None
22 kA
RC2M200S [11]
1
1
QOM2-VH
QO-VH
200 A
 50 A
A 6–350
(2)8–2/0
27, 20
Horn
RC2M200SH [11]
A 6–350
(2)8–2/0
27, 20
Lever 10 kA
RC2M200SL [11] [12]
1
QOM2-VH
200 A
A 6–350
8-1/0
60 / 14
1
QO-VH
50 A 8-1/0
None 22 kA
QC12L200S [11] [12]
[13]
6
QO-VH
200 A A 6–350 8–2/0
43, 21
None 22 kA
QC12L200C [11]
6
QO-VH
200 A
[6]
A 6–350 12-2/0
40, 21
Surface Mount Only, Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers
100 A Horn OH/UG 22 kA
QC816F100CH [7] [11]
[12]
1
QOM2100VH
[9]
100 A 8 16 8 100 A 6–350 12-2/0
40, 21
125 A
None OH/UG 22 kA
QC816F125S [7][11]
[12]
1
QOM2125VH
[9]
125 A 8 16 8 100 A 6–350 8–2/0
43, 21
None OH/UG 22 kA
QC816F125C [7][11]
1
QOM2125VH
[9]
125 A 8 16 8 100 A 6–350 12-2/0
40, 21
150 A
None OH/UG 22 kA
QC816F150S [7][11]
[12] [13]
1
QOM2150VH
[9]
150 A 8 16 8
150 A
[14]
A 6–350 8–2/0
43, 21
None OH/UG 22 kA
QC816F150C [7][11]
1
QOM2150VH
[9]
150 A 8 16 8
150 A
[14]
A 6–350 12-2/0
40, 21
Lever OH/UG 22 kA
QC816F150SL [7] [11]
[12] [13]
1
QOM2150VH
[9]
200 A 8 16 8 150 A A 6–350 8-2/0 74 / 12
200 A
None OH/UG 22 kA
QC816F200S [7] [11]
[12] [13]
1
QOM2200VH
[9]
200 A 8 16 8
200 A
[6]
A 6–350
8–2/0
43, 21
Horn OH/UG 22 kA
QC816F200SH [7][11]
[12] [13]
1
QOM2200VH
[9]
200 A 8 16 8
200 A
[6]
A 6–350
Horn OH/UG 22 kA
QC816F200CH [7] [11]
1
QOM2200VH
[9]
200 A 8 16 8
200 A
[6]
A 6–350 12-2/0
40, 21
Lever OH/UG 22 kA
QC816F200SL [7] [11]
[12] [13]
1
QOM2200VH
[9]
200 A 8 16 8 200 A A 6–350 8–2/0 74 / 12
Ringless, Homeline
TM
Surface Mount Only
125 A None OH/UG 10 kA
RC8L125S[15]
4 HOM
125 A
[16]
A 6–2/0 6–2/0
27, 32
1
LOAD CENTERS
[1] To order branch circuit breakers, see QO Plug-On Circuit Breakers, page 1-3
[2] To order hubs, see Accessories and Hubs for CSEDs, page 1-40
[3] To order service disconnects, see Circuit Breakers for CSEDs, page 1-39 except as noted)
[4] Use only 15–110 A and 150–200 A breakers.
[5] Suitable for OH service with addition of tunnel kit (SCTK20). Order separately.
[6] Use only 15–100 A and 150–200 A circuit breakers.
[7] Supplied with load side feed-thru lugs, for 4 AWG–250 kcmil (Al/Cu) conductors.
[8] Convertible to semiflush with SC200F flange kit (order separately).
[9] Service disconnect supplied factory-installed.
[10] A 100 A circuit breaker can be installed in bottom position only, all other positions are limited to 70 A max.
[11] Device supplied with barrel lock provisions factory-installed.
[12] 5th jaw factory-installed.
[13] Suitable for load wires to exit top endwall with addition of Tunnel Kit OHBS, see Table 1.86 Accessories, page 1-40, check with local utility for approval.
[14] Use only 15–100 A and 150 A circuit breakers.
[15] Knockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories).
[16] 125 A Homeline™ 2P circuit breaker can be installed in top position only. All other positions are limited to 100 A max.