Circuit Breaker Installation for Homeline
®
Combination Service Entrance Devices 40270-308-05
Instruction Bulletin Rev. 01, 02/2014
Electrical equipment should be installed, operated, serviced, and
maintained only by qualified personnel. No responsibility is assumed
by Schneider Electric for any consequences arising out of the use of
this material.
© 2014 Schneider Electric USA All Rights Reserved
™
Identify Circuits
Identify branch circuits on directory label or directory stickers.
Energize the Circuit
NOTE: Before energizing combination service entrance devices, turn
main and branch circuit breakers to the OFF position.
1. Turned on power to the combination service entrance device.
2. Turn main circuit breaker ON.
3. Turn on branch circuit breakers.
Handle at mid position indicates the circuit breaker is tripped. To
reset, move handle to the off position and then to the on position.
Figure 9:
Removal of Circuit Breakers
1. Turn circuit breakers OFF.
2. Remove wires.
3. Disconnect plug-on jaws from bus bar connection by pulling circuit
breaker outward until it disengages from mounting hook.
ON
OFF
ON
OFF
11003019
ON
OFF
Tripped