User's Manual

62
STRIDE2400 Terminal Station Setup Guide
3.3.3.4 Connecting the Subscriber Lines to the Line Termination Block
After the subscriber lines are connected to the STS Power Pack, they must be connected to the
subscriber’s line termination block (LTB).
Requirements:
d Make sure that the power switch on the STS Power Pack is set to off (down position), before
making any wire connections.
E
To connect the subscriber lines to the LTB
1. Insert the service drop jumper cable through either cable entry glands of the STS Power Pack as
shown in Figure 3.17 on page 59.
2. Connect Tip 1 and Ring 1 on TB1 to line 1 on the subscriber’s LTB as shown in Figure 3.19 on
page 63.
3. Connect Tip 2 and Ring 2 on TB1 to line 2 on the subscriber’s LTB (if required).
4. Tighten the two cable entry glands to lock the cables in place.
5. Wrap the cable entry glands first with vulcanized tape, then with electrical tape, to weatherproof the
connection. Make sure to wrap the cable entry glands in the clockwise direction to tighten the
connection.
Customer Provided: Service drop jumper cable
Tools: Small flat-blade screwdriver, wire cutter/stripper