User's Manual
Table Of Contents
- 1 Glossary 5
- 2 Notices 6
- 3 Introduction 9
- 4 AIS AtoN product variants 13
- 5 Installation 14
- 6 Transceiver and Sensor Interface connections 19
- 7 Connecting external sensors and systems 23
- 8 Configuration using proAtoN 31
- 9 Operation 50
- 10 Data messages and data sources 51
- 11 Manual configuration 59
- 12 Technical specification 68
- 13 Firmware upgrade procedure 73
- 1 Glossary
- 2 Notices
- 3 Introduction
- 4 AIS AtoN product variants
- 5 Installation
- Figure 3 Typical AIS AtoN transceiver system connections
- Figure 4 Typical AIS AtoN transceiver and Sensor Interface system connections
- 1. Mount the Transceiver in a suitable location on the physical Aid to Navigation.
- 2. Install a VHF antenna according to the manufacturers instructions.
- 3. Install the supplied GNSS antenna.
- 4. Connect any sensor interfaces and light / RACON monitoring signals.
- 5. Connect power to the AIS AtoN transceiver and optional Sensor Interface.
- 6. Configure and commission the AIS AtoN transceiver and optional Sensor Interface via USB (note that this step can be carried out on shore prior to installation in a remote location).
- 5.1 What’s in the box (AIS AtoN transceiver)
- 5.2 What’s in the box (Sensor Interface)
- 5.3 Preparing for installation
- 5.3.1 Tools and wiring accessories
- 5.3.2 VHF antenna and cable
- 5.3.3 PC for configuration
- 5.4 Mounting the AIS AtoN transceiver and Sensor Interface
- 6 Transceiver and Sensor Interface connections
- 6.1 AIS AtoN transceiver connections
- 6.1.1 Power and USB connector
- 6.1.2 18 way Link connector
- 6.1.3 Using the 18 way link connector for direct connection of external equipment
- 6.1.4 VHF antenna connector
- 6.1.5 GNSS antenna connector
- 6.1.6 Earth connection stud
- 6.2 Sensor Interface connections
- 6.2.1 USB connector
- 6.2.2 Sensor 1 connector
- 6.2.3 Sensor 2 connector
- 6.2.4 Link connector
- 7 Connecting external sensors and systems
- 7.1 Connecting sensors and systems to the AIS AtoN Transceiver
- 7.1.1 Light ON/OFF interface
- 7.1.2 Light health interface
- 7.1.3 RACON status interface
- 7.1.4 AtoN Status source and configuration
- 7.1.5 NMEA0183 port
- 7.2 Connecting sensors and systems to the Sensor Interface
- 7.2.1 Isolated analogue inputs
- 7.2.2 Non-isolated analogue inputs
- 7.2.3 Light current sense loop
- 7.2.4 Isolated digital inputs
- 7.2.5 Non-isolated digital inputs/outputs
- 7.2.6 Isolated RS422 / NMEA0183 port
- 7.2.7 RS232 ports
- 7.2.8 SDI-12 interface
- 7.2.9 Relay drive output
- 7.2.10 Input voltage monitor
- 8 Configuration using proAtoN
- 8.1 proAtoN installation
- 8.2 Application layout
- 8.2.1 COM Port selection
- 8.2.2 Read / Write configuration
- 8.2.3 Transceiver configuration mode tabs
- 8.2.4 Sensor configuration mode tabs
- 8.2.5 Synchronisation status
- 8.2.6 Status bar
- 8.3 AIS AtoN transceiver configuration
- 8.3.1 Configuration of ‘Real’ AtoN parameters
- 8.3.2 Message schedule configuration
- Default messages
- Adding additional messages to the schedule
- Access scheme selection
- 8.3.3 FATDMA Schedule configuration
- Channel 1 start UTC
- Channel 1 start slot
- Channel 1 interval
- Channel 2 start UTC
- Channel 2 start slot
- Channel 2 interval
- Example FATDMA schedule
- 8.3.4 RATDMA Schedule configuration
- Channel 1 start UTC
- Channel 1 interval
- Channel 2 start UTC
- Channel 2 interval
- Example RATDMA schedule
- 8.3.5 Virtual AtoN configuration
- Virtual / Synthetic AtoN
- Virtual / Synthetic AtoN Details
- Virtual AtoN schedule
- 8.3.6 Status input configuration tab
- Current status (message 21)
- Light & RACON configuration
- Status bit source
- Status bit logic
- 8.3.7 Alert messages
- BIIT failure actions
- Vessel proximity alert
- Off position alert
- SART Relay Mode
- 8.4 Transceiver diagnostics
- 8.4.1 GNSS tab
- 8.4.2 Serial data tab
- 8.4.3 Diagnostics tab
- AtoN Details
- Power status
- Report generation
- Reported messages
- Active alarms
- 8.5 Sensor configuration
- 8.5.1 Sensor settings
- 8.5.2 ADC settings tab
- Light Current Sense group
- Current Sense ADC Scaling
- Voltage Measurement Scaling
- 8.5.3 Message settings tab
- Message #6 Configuration
- Message #8 Configuration
- 8.5.4 System information
- System Information
- Digital Input Status
- Sensor Health
- 8.5.5 Live data tab
- ADC Data
- 8.6 Other features
- 8.6.1 Offline configuration (applies to transceiver configuration mode only)
- 9 Operation
- 10 Data messages and data sources
- 10.1 Configurations without the Sensor Interface
- 10.2 Configurations with the Sensor Interface
- 10.2.1 AIS AtoN transceiver configuration
- 10.2.2 Configuration of the Sensor Interface
- 10.2.3 Accessing the Sensor Interface shell
- 10.2.4 General Sensor Interface configuration commands
- 10.2.5 Zeni Lite Message #6 configuration commands
- 10.2.6 ADC configuration commands
- 10.2.7 ADC Scaling
- 10.2.8 Message #6 Data Mapping
- 10.2.9 External device support
- 11 Manual configuration
- 11.1 Basic Type 1 AIS AtoN configuration (FATDMA operation)
- 11.2 NMEA0183 / IEC61162 configuration sentences
- 11.2.1 AAR - Configure broadcast rates for AtoN station
- 11.2.2 ACE - Extended general AtoN Station configuration
- 11.2.3 ACF - General AtoN Station configuration
- 11.2.4 AFB - Forced broadcast
- 11.2.5 AFC - AtoN function ID capability
- 11.2.6 AID - MMSI configuration
- 11.2.7 ARW -Configure the receiver turn-on times
- 11.2.8 MCR - Configure proprietary AtoN control
- 11.2.9 MPR - Message configuration of payload re-broadcast
- 11.2.10 TSP - Transmit slot prohibit
- 11.2.11 VER - Version
- 11.3 Proprietary configuration sentences
- 11.3.1 Status Bit Source
- 11.3.2 Status Bit Source Query
- 11.3.3 Light / RACON configuration
- 11.3.4 Light / RACON configuration query
- 11.3.5 General MCR query
- 12 Technical specification
- 12.1 Applicable equipment standards
- 12.2 AIS AtoN transceiver specification
- 12.2.1 Physical
- 12.2.2 Environmental
- 12.2.3 Electrical
- 12.2.4 GNSS
- 12.2.5 TDMA transmitter
- 12.2.6 TDMA receivers
- 12.2.7 Supported AIS messages (transmission)
- 12.2.8 Connector types
- 12.3 Sensor Interface specification
- 12.3.1 Physical
- 12.3.2 Environmental
- 12.3.3 Interfaces
- 12.4 Drawings and dimensions
- 13 Firmware upgrade procedure
- 1. Install and run the 'vxsend' utility (screenshot shown in Figure 33).
- 2. Click the Browse (…) button for the Image file, then navigate to and select the appropriate update file.
- 3. Select the COM port assigned to the AIS AtoN port or AIS AtoN Sensor port, depending on which element is being updated.
- 4. Click 'Start' and wait for the update to complete. Notification is given when the update has completed successfully.
- 5. Power cycle the transceiver and confirm normal operation before it is deployed.
Data messages and data sources
Page 58
Table 8 Data mapping for message #6 Zeni Lite format
10.2.9 External device support
The unit currently supports the following external devices which can be configured in number of combinations
(“options”) and the data used to populate message #8 Meteorological and Hydrological data. Two formats of
this message are supported; DAC 001, FI 31 and DAC 001, FI 11.
● Airmar PB200 / 150WX Weather Station
● Impress S12C Water Pressure and Temperature gauge
● RM Young Wind Monitor
● JFE Advantech Co. Current Meter AEM-RS
● Vaisala Weather Transmitter WXT520
● SeaLite light serial interface
● RM Young weather station
● Nortek AS Aquadopp Profiler
● Gill Metpak Weather Station
● Valeport TideMaster tide gauge
Separate guides are available for each device detailing the connection and configuration arrangements. Only
certain arrangements of sensors are possible due to the limitations of the Sensor Interface as shown in
Table 9.
By default the Sensor Interface is configured to interface to the Airmar weather station via either the RS422 or
RS232 A port and the Impress water meter via the RS232 B port. Please contact your supplier for details of
how to configure the Sensor Interface to operate with other devices.
The Sensor Interface can also be adapted to support almost any equipment that might be encountered in an
AtoN application. If your application requires interface to equipment other than that listed here please contact
your supplier to discuss your requirements.
Power Supply Type User Input See section 10.2.5
Light Status Isolated DI 1 or ISENSE ADC 2
Battery Status
Voltage Data value compared with
user input threshold.
Only functions if power
supply type is DC
Off-position Status Transceiver off position algorithm
Transceiver off position
algorithm
Message #6 Zeni Lite Format Data Source Notes