User's Manual

The compliance of KDB 996369 D02 Module Q&A v01Question 11:
The external omni antenna is connected directly to the module by IPEX cable without passing through
other peripheral circuits, so this requirement is not applicable to the product.
The requirement for KDB 996369 D03:
1 List of applicable FCC rules
FCC Part 15. 247
2 Summarize the specific operational use conditions
None.
3 Limited module procedures
The module is a single module, so this requirement is not applicable to the product.
4 Trace antenna designs
The external omni antenna is connected directly to the module by IPEX cable, so this requirement is not
applicable to the product.
Typical Dimension(W x L x T): 49mm x 25mm x 3.3mm (+/- 0.2mm)
PCB Thickness: 0.8mm(+/- 0.1mm)