Datasheet

®
1/7
Table 1: Main Features
DESCRIPTION
Available either in through-hole or surface-mount
packages, the BTA06 and BTB06 triac series is
suitable for general purpose AC switching. They
can be used as an ON/OFF function in applica-
tions such as static relays, heating regulation, in-
duction motor starting circuits... or for phase
control operation in light dimmers, motor speed
controllers,...
The snubberless and logic level versions (BTA/
BTB...W) are specially recommended for use on
inductive loads, thanks to their high commutation
performances.
By using an internal ceramic pad, the BTA series
provides voltage insulated tab (rated at
2500V
RMS
) complying with UL standards (File ref.:
E81734).
Symbol Value Unit
I
T(RMS)
6A
V
DRM
/V
RRM
600 and 800 V
I
GT (Q
1
)
5 to 50 mA
BTA06 and BTB06 Series
6A TRIACS
REV. 6February 2006
SNUBBERLESS™, LOGIC LEVEL & STANDARD
Table 2: Order Codes
Part Number Marking
BTA06-xxxxxRG
See page table 8 on
page 6
BTB06-xxxxxRG
G
A2
A1
G
A2
A2
A1
TO-220AB Insulated
(BTA06)
TO-220AB
(BTB06)
A2
A1
G
Table 3: Absolute Maximum Ratings
Symbol Parameter Value Unit
I
T(RMS)
RMS on-state current (full sine
wave)
TO-220AB
T
c
= 110°C
6A
TO-220AB Ins.
T
c
= 105°C
I
TSM
Non repetitive surge peak on-state
current (full cycle, T
j
initial = 25°C)
F = 50 Hz t = 20 ms 60
A
F = 60 Hz t = 16.7 ms 63
I
²
tI
²
t Value for fusing
t
p
= 10 ms
21
A
²
s
dI/dt
Critical rate of rise of on-state cur-
rent I
G
= 2 x I
GT
, t
r
100 ns
F = 120 Hz
T
j
= 125°C
50 A/µs
I
GM
Peak gate current
t
p
= 20 µs T
j
= 125°C
4A
P
G(AV)
Average gate power dissipation
T
j
= 125°C
1W
T
stg
T
j
Storage junction temperature range
Operating junction temperature range
- 40 to + 150
- 40 to + 125
°C

Summary of content (7 pages)