Datasheet

ELECTRICAL CHARACTERISTICS (Continued)
LOGIC CONTROL TO POWER DRIVE TIMING
Symbol Parameter Test Conditions Min. Typ. Max. Unit
t
1
(V
i
) Source Current Turn-off Delay Fig. 12 300 ns
t
2
(V
i
) Source Current Fall Time Fig. 12 200 ns
t
3
(V
i
) Source Current Turn-on Delay Fig. 12 400 ns
t
4
(V
i
) Source Current Rise Time Fig. 12 200 ns
t
5
(V
i
) Sink Current Turn-off Delay Fig. 13 300 ns
t
6
(V
i
) Sink Current Fall Time Fig. 13 200 ns
t
7
(V
i
) Sink Current Turn-on Delay Fig. 13 400 ns
t
8
(V
i
) Sink Current Rise Time Fig. 13 200 ns
(*) Limited by power dissipation
(**) In synchronous rectification the drain-source voltage drop VDS is shown in fig. 4 (L6202/03); typical value for the L6201 is of 0.3V.
Figure 1: Typical Normalized I
S
vs. T
j
Figure 3: Typical Normalized I
S
vs. V
S
Figure 2:
Typical Normalized QuiescentCurrent
vs. Frequency
Figure 4: Typical R
DS (ON)
vs. V
S
~V
ref
L6201 - L6201P - L6202 - L6203
5/20