Datasheet

DC and AC parameters M24C16, M24C08, M24C04, M24C02, M24C01
22/39 Doc ID 5067 Rev 16
Figure 11. AC measurement I/O waveform
Table 12. DC characteristics (M24Cxx-F)
Symbol Parameter
Test condition
(in addition to those in Tabl e 8 )
Min. Max. Unit
I
LI
Input leakage current (SCL, SDA,
E0, E1,and E2)
V
IN
= V
SS
or
V
CC
, device in Standby
mode
± 2 µA
I
LO
Output leakage current V
OUT
= V
SS
or
V
CC,
SDA in Hi-Z ± 2 µA
I
CC
Supply current
V
CC
= 1.7 V, f
c
= 400 kHz
(rise/fall time < 50 ns)
0.8 mA
I
CC1
Standby supply current
Device not selected
(1)
, V
IN
= V
SS
or
V
CC
, V
CC
= 1.7 V
A
V
IL
Input low voltage (SDA, SCL, WC)
2.5 V V
CC
–0.45 0.3 V
CC
V
1.7 V V
CC
< 2.5 V –0.45 0.25 V
CC
V
V
IH
Input high voltage (SDA, SCL, WC)0.7V
CC
V
CC
+1 V
V
OL
Output low voltage I
OL
= 0.7 mA, V
CC
= 1.7 V 0.2 V
1. The device is not selected after a power-up, after a read command (after the Stop condition), or after the completion of the
internal write cycle t
W
(t
W
is triggered by the correct decoding of a write command).
Table 13. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
bus
Load capacitance 100 pF
SCL input rise/fall time, SDA input fall time 50 ns
Input levels 0.2V
CC
to 0.8V
CC
V
Input and output timing reference levels 0.3V
CC
to 0.7V
CC
V
AI00825B
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
Input and Output
Timing Reference Levels
Input Levels
Table 14. Input parameters
Symbol Parameter
(1)
Test condition Min. Max. Unit
C
IN
Input capacitance (SDA) 8 pF
C
IN
Input capacitance (other pins) 6 pF
Z
WCL
WC input impedance V
IN
< 0.3 V 15 70 kΩ
Z
WCH
WC input impedance V
IN
> 0.7V
CC
500 kΩ
t
NS
Pulse width ignored (input filter on
SCL and SDA)
Single glitch 100 ns
1. Characterized only.