Datasheet

Characteristics STTH8R06
2/12
1 Characteristics
To evaluate the conduction losses use the following equation: P = 1.16 x I
F(AV)
+ 0.08 I
F
2
(RMS)
Table 2. Absolute ratings (limiting values)
Symbol Parameter Value Unit
V
RRM
Repetitive peak reverse voltage 600 V
I
F(RMS)
Forward current rms
TO-220AC / TO-220FPAC / D
2
PAK / I
2
PA K 30
A
TO-220AC Ins. 24
I
F(AV)
Average forward current
δ = 0.5
TO-220AC / D
2
PAK / I
2
PAK Tc = 130 °C
8ATO-220FPAC Tc = 85 °C
TO-220AC Ins. Tc = 100 °C
I
FSM
Surge non repetitive forward current tp = 10ms sinusoidal 80 A
T
stg
Storage temperature range -65 to + 175 °C
T
j
Maximum operating junction temperature 175 °C
Table 3. Thermal resistance
Symbol Parameter Value (max) Unit
R
th(j-c)
Junction to case
TO-220AC / D
2
PAK / I
2
PA K 2 . 2
°C/WTO-220FPAC 4.6
TO-220AC Ins. 3.8
Table 4. Static electrical characteristics
Symbol Parameter Test conditions Min Typ Max Unit
I
R
Reverse leakage current
T
j
= 25 °C
V
R
= V
RRM
30
µA
T
j
= 125 °C 35 400
V
F
Forward voltage drop
T
j
= 25 °C
I
F
= 8 A
2.9
V
T
j
= 125 °C 1.4 1.8
Table 5. Dynamic characteristics
Symbol Parameter Test conditions Min Typ Max Unit
t
rr
Reverse recovery time T
j
= 25 °C
I
F
= 0.5 A, I
rr
= 0.25 A, I
R
=1 A 25
ns
I
F
= 1 A, dI
F
/dt = -50 A/µs, V
R
= 30 V 45
I
RM
Reverse recovery current
T
j
= 125 °C
I
F
= 8 A, V
R
= 400 V,
dI
F
/dt = -200 A/µs
5.5 7.2 A
S factor Softness factor 0.3
Qrr Reverse recovery charges 150 nC
t
fr
Forward recovery time
T
j
= 25°C
I
F
= 8 A, dI
F
/dt = 64 A/µs
V
FR
= 1.1 x V
Fmax
150 ns
V
FP
Forward recovery voltage 5 V