Datasheet

Absolute maximum ratings and operating
conditions
TL072, TL072A, TL072B
4/16
DocID2298 Rev 8
2 Absolute maximum ratings and operating conditions
Table 1: Absolute maximum ratings
Symbol Parameter TL072I, AI, BI TL072C, AC,
BC
Unit
V
CC
Supply voltage
(1)
±18 V
V
in
Input voltage
(2)
±15
V
id
Differential input voltage
(3)
±30
R
thja
Thermal resistance junction to ambient,
SO8
(4)
125 °C/W
R
thjc
Thermal resistance junction to case,
SO8
(4)
40
Output short-circuit duration
(5)
Infinite
T
stg
Storage temperature range -65 to +150 °C
ESD
HBM: human body model
(6)
1 kV
MM: machine model
(7)
200 V
CDM: charged device model
(8)
1.5 kV
Notes:
(1)
All voltage values, except the differential voltage, are with respect to the zero reference level (ground) of the
supply voltages where the zero reference level is the midpoint between V
CC
+
and V
CC
-
.
(2)
The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 volts,
whichever is less.
(3)
Differential voltages are the non-inverting input terminal voltages with respect to the inverting input terminal.
(4)
Short-circuits can cause excessive heating. Destructive dissipation can result from simultaneous short-
circuits on all amplifiers.
(5)
The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be
limited to ensure that the dissipation rating is not exceeded.
(6)
Human body model: 100 pF discharged through a 1.5 kΩ resistor between two pins of the device. This is
done for all couples of pin combinations with other pins floating.
(7)
Machine model: a 200 pF cap is charged to the specified voltage, then discharged directly between two pins
of the device with no external series resistor (internal resistor < 5 W). This is done for all couples of pin
combinations with other pins floating.
(8)
Charged device model: all pins plus package are charged together to the specified voltage and then
discharged directly to the ground.
Table 2: Operating conditions
Symbol Parameter TL072I, AI,
BI
TL072C, AC,
BC
Unit
V
CC
Supply voltage 6 to 36 V
T
oper
Operating free-air temperature range -40 to +125 0 to +70 °C