TS556 Low-power dual CMOS timer Datasheet - production data Description The TS556 is a dual CMOS timer which offers a very low consumption: (Icc(TYP) TS556 = 220 µA at VCC = 5 V versus Icc(TYP) NE556(a) = 6 mA), SO14 (plastic micropackage) and high frequency: (f(max.) TS556 = 2.7 MHz versus f(max.) NE556(a) = 0.1 MHz) Pin connections (top view) In both monostable and astable modes, timing remains very accurate.
Contents TS556 Contents 1 Absolute maximum ratings and operating conditions . . . . . . . . . . . . . 3 2 Schematic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4 Application information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 5 4.1 Monostable operation . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TS556 1 Absolute maximum ratings and operating conditions Absolute maximum ratings and operating conditions Table 1.
R1 4/19 R2 DocID4078 Rev 3 50k Ω R6 50k Ω R5 50k Ω R4 50k Ω R3 C ontrol Volta ge 50k Ω Τ1 Τ5 Τ4 Τ2 Τ6 Thres hold Τ7 Τ8 Τ9 R7 Τ11 Τ10 Τ14 Τ15 Τ12 Τ18 Τ13 GND Τ16 Τ20 CC R ESET Τ17 Τ19 T rigger Τ21 Τ22 Τ23 Τ25 Τ24 Τ26 Τ28 Τ27 Τ29 Τ30 Τ32 Τ31 Τ33 Τ35 Dis charge Τ34 Output 2 50k Ω V Schematic diagram TS556 Schematic diagram Figure 1.
TS556 Schematic diagram Figure 2. Block diagram VCC Reset TS556 4 / 10 14 R R1 2 / 12 Threshold Control Voltage Q + Output 5/9 R - A 3 / 11 S R + Trigger 6/8 - B R 1 / 13 Discharge 7 Ground Table 3.
Electrical characteristics 3 TS556 Electrical characteristics Table 4. Static electrical characteristics VCC = 2 V, Tamb = 25 °C, reset to VCC (unless otherwise specified) Symbol 6/19 Parameter Min. Typ. Max. Unit 130 400 400 µA 1.3 1.4 1.5 0.05 0.2 0.25 1 100 0.1 0.3 0.
TS556 Electrical characteristics Table 5. Static electrical characteristics VCC = 3 V, Tamb = 25 °C, reset to VCC (unless otherwise specified) Symbol Parameter Min. Typ. Max. Unit 180 460 460 µA 2 2.2 2.3 0.05 0.2 0.25 1 100 0.1 0.3 0.
Electrical characteristics TS556 Table 6. Dynamic electrical characteristics VCC = 3 V, Tamb = 25 °C, reset to VCC (unless otherwise specified) Symbol Parameter Min. Timing accuracy (monostable) (1) R = 10 kΩ, C = 0.1 µF, VCC= 2 V R = 10 kΩ, C = 0.1 µF, VCC = 3 V fmax 0.5 Timing shift with temperature (1) Tmin ≤Tamb ≤Tmax 75 Maximum astable frequency (2) RA = 470 Ω, RB = 200 Ω, C = 200 pF 2 — 5 0.
TS556 Electrical characteristics Table 7. Static electrical characteristics VCC = 5 V, Tamb = 25 °C, reset to VCC (unless otherwise specified) Symbol Parameter Min. Typ. Max. Unit 220 500 500 µA 3.3 3.8 3.9 0.2 0.3 0.35 1 100 0.3 0.6 0.
Electrical characteristics TS556 Table 8. Dynamic electrical characteristics VCC = 5 V, Tamb = 25 °C, reset to VCC (unless otherwise specified) Symbol Parameter Min. Timing accuracy (monostable) (1) R = 10 kΩ, C = 0.1 µF Maximum astable frequency (2) RA = 470 Ω, RB = 200 Ω, C = 200 pF 2.7 Output fall time (Cload = 10 pF) 20 Trigger propagation delay 100 Minimum reset pulse width (Vtrig = 5 V) 350 DocID4078 Rev 3 % 0.1 tF 2. See Figure 6 MHz %/V 25 1.
TS556 Electrical characteristics Table 9. Static electrical characteristics VCC = 12 V, Tamb = 25 °C, reset to VCC (unless otherwise specified) Symbol Parameter Min. Typ. Max. Unit 340 800 800 µA 8 8.6 8.7 0.09 1.6 2.0 1 100 1.2 2 2.
Electrical characteristics TS556 Figure 3.
TS556 Application information 4 Application information 4.1 Monostable operation In monostable mode, the timer operates like a one-shot generator. Referring to Figure 2, the external capacitor is initially held discharged by a transistor inside the timer, as shown in Figure 4. Figure 4. Application schematic VC C Reset R Trigger 1/2 TS556 C Out Control Voltage 0.01 F The circuit triggers on a negative-going input signal when the level reaches 1/3 VCC.
Application information 4.2 TS556 Astable operation When the circuit is connected as shown in Figure 6 (pins 2 and 6 connected) it triggers itself and runs as a multivibrator. The external capacitor charges through RA and RB and discharges through RB only. Thus the duty cycle may be precisely set by the ratio of these two resistors. In the astable mode of operation, C charges and discharges between 1/3 VCC and 2/3 VCC.
TS556 5 Package information Package information In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK® packages, depending on their level of environmental compliance. ECOPACK® specifications, grade definitions and product status are available at: www.st.com. ECOPACK® is an ST trademark.
Package information 5.1 TS556 SO14 package information Figure 8. SO14 package outline Table 11. SO14 mechanical data Dimensions Millimeters Inches Ref. Min. Typ. Max. Min. 1.35 1.75 0.05 0.068 A1 0.10 0.25 0.004 0.009 A2 1.10 1.65 0.04 0.06 B 0.33 0.51 0.01 0.02 C 0.19 0.25 0.007 0.009 D 8.55 8.75 0.33 0.34 E 3.80 4.0 0.15 0.15 1.27 0.05 H 5.80 6.20 0.22 0.24 h 0.25 0.50 0.009 0.02 L 0.40 1.27 0.015 0.05 k ddd 16/19 Max. A e Note: Typ.
TS556 6 Ordering information Ordering information Table 12.
Revision history 7 TS556 Revision history Table 13. Document revision history Date Revision 01-Feb-2003 1 Initial release. 2 Document reformatted. Added output current, ESD and thermal resistance values in Table 1: Absolute maximum ratings. Added output current values in Table 2: Operating conditions. Updated Section 5.1: DIP14 package information and Section 5.1: SO14 package information. 3 Features and Description: added footnote to NE556 product to explain it is terminated.
TS556 IMPORTANT NOTICE – PLEASE READ CAREFULLY STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on ST products before placing orders. ST products are sold pursuant to ST’s terms and conditions of sale in place at the time of order acknowledgement.