Datasheet

Electrical specifications VN5160S-E
10/31 Doc ID 13493 Rev 5
Table 8. Status pin (V
SD
=0)
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
STAT
Status low output voltage I
STAT
= 1.6 mA, V
SD
= 0V 0.5 V
I
LSTAT
Status leakage current
Normal operation or V
SD
= 5V,
V
STAT
= 5V
10 µA
C
STAT
Status pin input
capacitance
Normal operation or V
SD
=5V,
V
STAT
= 5V
100 pF
V
SCL
Status clamp voltage
I
STAT
= 1mA
I
STAT
= - 1mA
5.5
-0.7
7V
V
Table 9. Protection
(1)
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short circuit current
V
CC
= 13V
5V<V
CC
<36V
3.8 5.4 7.5
7.5
A
A
I
limL
Short circuit current during
thermal cycling
V
CC
= 13V; T
R
<T
j
<T
TSD
2A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature
T
RS
+ 1
T
RS
+ 5 °C
T
RS
Thermal reset of STATUS 135 °C
T
HYST
Thermal hysteresis (T
TSD
-T
R
)
C
t
SDL
Status delay in overload
conditions
T
j
>T
TSD
20 µs
V
DEMAG
Turn-off output voltage
clamp
I
OUT
=150mA; V
IN
=0 V
CC
-41 V
CC
-46 V
CC
-52 V
V
ON
Output voltage drop
limitation
I
OUT
= 0.03A;
T
j
=-40°C...+150°C
(see Figure 5)
25 mV