If a tolerance has been exceeded when performing the vertical check, the laser can
be re-adjusted as follows. Switch the laser off. To go to Adjustment mode, hold
down button (4a) first. Additionally press button (3). as soon as the y LED illumina-
tes, release button (4a).
The Z LED now flashes rapidly.
The laser can now be adjusted in the Z-axis.
The laser is correctly adjusted when the laser dot is precisely centred between
Points 1 and 3 for the vertical check. Adjust the dot's height using buttons (17) and
(18) on the remote control until it is precisely between Points 1 and 3.
Adjustment - Vertical
The laser is now adjusted again. Pressing button (14) on the remote control saves
the settings. If you do not wish to save the setting, exit Adjustment mode without
saving by pressing the button (3) on the laser. The old setting is then kept
unchanged.
Saving the adjustment
Replacing the
batteries