User manual

13
• Dirty lens glass on the beam emitter detracts from the quality of the beam.
It should be cleaned with a soft cloth.
• Clean the laser unit with a damp cloth. Do not spray or immerse the unit!
Do not use solvents or thinners!
Subject to technical modifications.
Care and maintenance
Stabila provides a guarantee against deficiencies and faults in the assured characteri-
stics because of material or manufacturing faults for a period of 24 months from date
of purchase. Any faults will be eliminated at Stabila's own discretion either by repai-
ring or replacing the unit. Stabila accepts no wider claims.
No liability is accepted for any faults due to inappropriate treatment (e.g. damage
caused by the unit falling, operation with the wrong voltage or type of current, use of
unsuitable current supply sources) or for any autonomous changes made to the unit
by the purchaser or a third party.
Also no claims under guarantee are accepted for natural wear and tear or any small
faults that do not significantly affect the unit's operation.
Any guarantee claims must be made via the dealer on the duly completed guarantee
form (see last page) to be returned with the unit.
Guarantee terms and conditions
Like any precision instrument, handle the LAX-200 crossed line laser carefully and
cautiously.
Laser type:
Technical data
Self-levelling range:
Output:
Batteries:
Operating life:
Operating temperature range:
Storage temperature range:
Red diode laser, pulsed line-laser
wavelength 630-660 nm
< 1 mW, Laser Class 2
to EN 60825-1:03-10
ca. ± 4,
3 x 1,5 V mignoncells alkaline, size AA, LR6
approx. 30 hours (alkaline)
-10 °C to +50 °C
-20 °C to +60 °C
laser line horizontal*: L1 = ± 0,3 mm/m laser line
L2 = ± 0,2 mm/m laser lineinclination of the laser line*:
L1
L2
Levelling accuracy:
* When operated within specified temperature range