Installation Instructions

14
Starting at the base of the inside corner pocket, press the two
glued surfaces together. Adhere the pocket to either wall (shown
in Figure 11A) with Multi-Purpose Bonding Adhesive. Install a
piece of Tape Flashing eight inches (8") wide extending from
the bottom of the pocket fold to the top. The Tape Flashing
should extend four inches (4") onto the pocket and four inches
(4") onto the wall. Caulk all edges of the tape ashing. (shown
in Figure 12).
TERMINATION BAR
Determine the height of the nished wall ashing (12" or less if
job conditions won't allow for full 12" height) and the placement
of the Termination Bar. Peel the top of the wall ashing from
the wall and apply a heavy bead of Water Stop between the
membrane and wall. The Water Stop should be applied so that
the nal position of the Termination Bar will be directly over
the Water Stop.
Fasten the Termination Bar with the appropriate fasteners.
Install a fastener in every per-drilled hole. Remove excess
membrane that extends above the Termination Bar and apply
Rubber Caulk to the top of the Bar.