Installation Guide

ASTM F1869 Standard Test Method for Meauring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous
Calcium Chloride
ASTM F 2170 Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs using In Situ Probes
ASTM F2419 Standard Practice for Installation of Thick Poured Gypsum Concrete Underlayments and Preparation of the
Surface to Receive Resilient Flooring
ASTM F2471 Standard Practice for Installation of Thick Poured Lightweight Cellular Concrete Underlayments and
Preparation of the Surface to Receive Resilient Flooring
ASTM F2659 Standard Guide for Preliminary Evaluation of Comparative Moisuter Condition of Concrete, Gypsum Cement
and Other Floor Slabs and Screeds Using a Non-Destructive Electronic Moisture Meter
ASTM F2678 Standard Practice for Preparing Panel Underlayments, Thick Poured Gypsum Concrete Underlayments,
Thick Poured Lightweight Cellular Concrete Underlayments, and Concrete Subfloors with Underlayment
Patching Compounds to Receive Resilient Flooring
ACI 302 Guide for Concrete Floor and Slab Construction
RFCI Recommended Work Practices for Removal of Resilient Floor Coverings
GENERAL GUIDELINES
This information provides general guidelines for STAINMASTER
®
luxury vinyl Clic FD product. All instructions and recommendations
should be followed for an ideal installation.
1. Install flooring perpendicular to direct sunlight sources, including large windows, doors, etc. as this will help to minimize the
expansion perpendicular to the light source.
2. Install STAINMASTER
®
luxury vinyl Clic FD product only after the jobsite has been cleaned and cleared of debris that could
potentially damage a finished plank installation.
3. Inspect your shipment of STAINMASTER
®
luxury vinyl Clic FD products to ensure that all cartons are of the
same lot/manufacturing run. Contact your retailer with any discrepancies or assistance with locating this information.
4. To minimize shade variation during the installation of STAINMASTER
®
luxury vinyl Clic FD product, mix and install planks
from several different cartons.
5. Acoustical underlayments must be Novalis branded products or specifically recommended by Novalis
®
International in writing.
Use of other underlayments not specifically designated by Novalis
®
will result in the Mechanical Warranty being voided.
6. All subfloor/underlayment patching must be done with a non-shrinking, water-resistant Portland cement patching compound.
7. The maximum room size suggested is limited to 30 linear feet with 5/16” spacing gap around the perimeter. STAINMASTER
®
luxury vinyl Clic FD product can grow if the temperature in the room increases by 18° F (7°C). For installations larger than 900
square feet (83.6 m2) or runs longer than 30 feet (9 meters) control joints must be installed with a minimum of 5/16” (8mm) gap
between the installed molding.
8. Doorways and archways 6 feet or less in width must have a suitable “T” molding installed as control joint to allow for normal
product movement between rooms. A minimum of 5/16” gap is to be allowed on either side of the installed track for the molding.
9. Do not use tapping blocks, adjustable spacers (screw type) or other tools common to hardwood and laminate flooring installation.
These tools will damage the vinyl flooring and prevent proper locking of the joint mechanisms.
10. This product cannot be installed with full spread adhesives. The use of any sort of adhesive during the installation will void the
product warranty.
MARCH 2017 2
Clic FD Flooring
Installation Instructions