User Manual

1-800-628-8810
9
BATTERIES:
1. Use a flat head screwdriver to open the battery compartment on the
backside of both the Handheld Display and Remote Sensor.
2. Install (3) AA Alkaline batteries into the Handheld Display according to
polarity.
3. Install (3) AAA Alkaline batteries into Remote Sensor according to
polarity.
4. Re-secure Handheld Display and Remote Sensor battery doors.
POWER ON:
1. Press power button on Handheld Display and Remote Sensor.
2. Confirm sync has been established by observing a pressure reading on
Handheld Display and by viewing signal strength icon.
VACUUM GAUGE SYSTEM CONNECT:
Connect Remote Sensor to Valve Core Removal Tool side flare or Refrigerant
Hose using Female-Female Adaptor if needed (included).
Best Practices:
Minimize the number of hoses and fitting connections
(including manifold) to reduce leaks.
• Use hilmor® Valve Core Removal Tool accessory port as close as
possible to the system for more accurate readings.
OPERATING
INSTRUCTIONS
TO CHANGE THE UNIT OF MEASURE ON THE HANDHELD DISPLAY
:
1. Hold down the Function button to open menu.
2. Press Function button to navigate to unIt submenu.
3. Press arrow button to change unit of measure: micron, mTorr, Torr,
mmHg, mBar, kPa and Pa.
4. Hold down Function button to save and exit.