User's Manual

Chapter 4: Setting up and Maintaining B.A.S.I.S.® Offline Locks
4 – 15
Notes
Diagnos-
tics Code
Hexadecimal number indicating firmware conditions,
such as firmware resets, that have occurred at the lock
since the diagnostics code was last cleared. The code
0x00 means no conditions have occurred.
To view the meaning of the code, tap the more button
(...). The Diagnostics Code window shows each active
diagnostics code and its meaning. See Figure 4.12. Tap
the close button (X) to close this win-
dow.
Technical support personnel may ask you to provide
this information.
To clear the diagnostics code, see page 4-20.
Online
Mode
Whether the lock is under time zone control (Auto-
matic) or set to a specific mode, such as Locked or
Unlocked. For more information, see “Changing a
lock’s online mode” on page 4–17
.
Use Count Number of times access was granted since the use
count was last reset. To reset the use count, see
page 4-19.
Main Bat-
tery
Current power level of the lock’s battery pack.
No shading in the status bar indicates an Alarm condi-
tion. The batteries are dead and must be replaced.
If the shading falls within the Warning range, the power
level is 30% or lower. You should replace the batteries
soon.
If the shading falls within the Good range, the power
level is between 30% and 100%.
Backup
Battery
Current power level of the lock’s coin cell battery, used
to back up the lock’s memory if the main battery pack
dies or is disconnected. If the backup battery is Bad,
you should replace it. Refer to the
B.A.S.I.S. G Service
Manual (T63300) or the B.A.S.I.S. V Service Manual
(T61805).
This field Shows
Figure 4.12 Diagnostics Code
window