User Manual
18 19
If your compressor does not start
• Check that you have plugged the power lead into a standard
240V 10Amp power point and turned the button ON.
• Check that you have turned the air compressor
ON/OFF button ON.
• The air tank may be full. Use your air tool and the air
compressor should start when the pressure decreases to
115PSI.
If your compressor does not build
up pressure
• Check that the tank drain tap is sealed.
If your compressor smells like burnt oil
• Check the oil level as it may be low
TROUBLE SHOOTING
PIC. 18
MAINTENANCE
Daily
Before use
1. Seal the tank drain tap, see Pic.14.
2. Check the oil level, see page 10, Pic. 4.
3. Check safety valve operation, see page 14, Pic. 12.
4. Check the belt tension, Pic 15, Page 16. Movement should
be 10-15mm. Adjust if required. Page 16.
5. Check for belt straightness. Adjust if required. Page 17.
After use
1. Open the tank drain tap, see Pic.14.
2. Wipe down the air compressor.
3. Store safely and securely.
Every 50 Hours
1. Replace the air filter, refer page 12.
2. Drain oil completely and replace with fresh oil
To drain:
a. Loosen and remove the drain bolt, Pic. 18 and drain oil into a
funnel / bottle and dispose of in an appropriate manner.
b. Once drained replace and tighten the drain bolt.
c. Wipe up any oil spills.
d. Fill up to the top red dot on the sight glass with fresh clean
oil. Refer page 10 for “To Add Oil, if Required” details.
Refer to diagram Pic. 4, page 10.
NOTE: Use oil type SAE30.
3. Check and replace the belt if necessary.
Remove oil drain
bolt and drain used
oil into funnel.
Replace and
tighten oil drain
bolt