DE-ASHING
When ash build-up becomes excessive in the fire
chamber shake the firebars by pushing and pulling
the riddling rod repeatedly. The riddling rod is locat-
ed under the base at the left side of the stove. See
Fig. 20.
REFUELLING
Riddle the fire by pulling the grate riddling knob back
and forward (see Fig. 20). Before opening the door,
open the primary air control fully as this will help to
eliminate any smoke or fly ash resident in the com-
bustion chamber. Add fuel to fire, close fire door and
re-set the air controls to the required setting.
SLOW BURNING
Slow burning will cause the window glass to blacken
and should not be used for a long period. It should
only be done after the fire has been established and
been running at nominal output for a period of time.
For a prolonged slow burn, fill the firebox of fuel up
to a maximum height just below the top of the fire
fence at the front of the door opening. Pull the pri-
mary air control knob up to close the primary air to
the minimum setting and set the secondary air con-
trol to the minimum setting, i.e. pull the secondary
air knob to close.
DISPOSAL OF ASHES
Your stove is provided with a stainless steel ashpan.
This ashpan should be emptied every day.
If ashes are allowed to build to grate level you could
damage the firebars by overheating. We recom-
mend that you remove ashes after you have riddled
the fire when the stove is thoroughly cooled.
Ashes should be placed in a metal or other non-
combustible container with a tight fitting lid. The
closed container of ashes should be placed on a
non-combustible material, pending final disposal. If
ashes are buried in soil, or otherwise dumped they
should be retained in the closed container until they
are thoroughly cooled.
Open the ashdoor and remove the ashpan using the
tool provided, see Fig 21. Close the ashdoor. When
the ash is disposed of replace the ashpan.
Fig 21
AIR CONTROLS
Anthracite Fully Open Fully Closed 0-80% Open Fully Closed
Coal Fully Open Fully Open 0-80% Open 0-50% Open
Wood/ Turf Fully Open Fully Open 0-10% Open 0-80% Open
Fuel Ignition Controlled Burn
Primary Secondary Primary Secondary
Fig.24