Technical Data
* under favourable conditions (good target surface,
room temperature) up to 10 m (33 ft). Under unfavour-
able conditions such as bright sunlight, a very weakly
reflecting target surface or large temperature fluctua-
tions, the error can increase to ± 0.25 mm/m
(± 0.003 in/ft) for distances over 10 m (33 ft).
Range 0.1 m to 30 m
0.33 ft to 160 ft
Measuring accuracy (2 σ) typ.: ± 2.0 mm* / ± 0.12 in*
Smallest unit displayed 1 mm / 1/16 in
Laser class 2
Laser type 635 nm, < 1 mW
Autom. power switch-off after 180 s
Battery durability (2 x AAA) up to 3000 measure-
ments
Dimension (H x D x W) 119 x 64 x 28 mm
4.67 x 2.52 x 1.10 in
Weight (with batteries) 100 g / 3.21 oz
Temperature range:
- Storage
- Operation
-25 to 70 °C
-13 to 158 °F
-0 to 40 °C
-32 to 104 °F
Functions
Distance measuring yes
Permanent measuring yes
Addition/Subtraction yes
Area yes
Volume yes
Display illumination yes