Takedown (Pursuit) and Alley LED Flasher Units
(LDF375-2 / 8070-375-2)
Output Pair
1
2
3
4
5
Brown
Yellow
Purple
Orange
White
Black
Red/Green
White = Steady 1 & 2 (Takedowns)
Orange = Steady 4 & 5 (Driver Alley)
Brown = Steady 3 (Passenger Alley)
Yellow = Flash 1 & 2 (Pursuits)
Black = Ground
Red/Green = Pattern Select
Purple = High/Low Power
Large Red = Power
L
a
r
g
e
R
e
d
Function Connect to Pairs
Takedown/Pursuit Lights 1 & 2
Passenger Alley 3
Driver Alley 4 or 5
B
l
u
e
/
G
r
e
e
n
(LED Pattern Programming CONT’D)
Takedown or Alley Light DLX6 and Batwing LED Patterns
(LDF375-2 Flasher)
Pattern Warning Pattern Style
1 Pursuit Mode (1 flash/3 sec default)
2 Alternating Slow Single (1,3 vs 2,4) (Title 13 Approved)
3 Alternate Pursuit Mode
4 Alternating Quad Flash (1,3 vs 2,4)
5 Alternating Triple (1,3 vs 2,4)
6 Alternating Quint (1,3 vs 2,4)
7 Simultaneous Slow Single (All Modules) (Title 13 Approved)
8 Simultaneous Fast Single (All Modules)
9 Simultaneous Triple Flash (All Modules)
10 Simultaneous Quad Flash (All Modules)
11 Simultaneous Quint Flash (All Modules)
12 Simultaneous Fast Triple Flash (All Modules)
13 Simultaneous Fast Quint Flash (All Modules)
14 In/Out Single (1,3 vs 2,4)
15 In/Out Triple (1,3 vs 2,4)
16 In/Out Quint (1,3 vs 2,4)
17 Simultaneous Double Flash, Post-Pop (2 flashes/6 sec default)
18 Simultaneous Triple Flash, Post-Pop
19 Simultaneous Quint Flash, Post-Pop
20 Alternating Double Flash, Post-Pop (1,3 vs 2,4)
21 Alternating Triple Flash, Post-Pop (1,3 vs 2,4)
22 Alternating Quint Flash, Post-Pop (1,3 vs 2,4)
23 Alternating Pre-Pop Quint Flash (1,3 vs 2,4)
24 Sequential Back And Forth (3 flashes/9 sec default)
25 Sequential In/Out
26 Burst All w/ Alternating Burst
27 Alternating Burst w/ Simultaneous Double Then Quint
28 Simultaneous Burst w/ Alternating Double Then Quint
29 Hyper-Random
30 Demo (Cycle Through Patterns 1-4,6-9,13-20,25-29)
The numbers in parenthesis in the list above indicate which output pairs flash
together vs. the pairs they flash opposite from.
Please Note: Please Note: At any time during the programming sequence, you can reset
the flash pattern back to any of the default patterns (Pattern 1, 18, or 24) by
holding the red w/green Pattern Select wire to +12VDC until the heads flash
the specified number of times, then release it.