3.4.2.1 Connecting to iPA for three sector case:
To Connect the iBTS to the iPA:
Connect the iBTS iPA 1 RJ-45 connector to the iPA COM 1 DB-9
connector with cable MCN 45-89330-M3.
Connect the iBTS iPA 2 RJ-45 connector to the iPA COM 2 DB-9
connector with cable MCN 45-89330-M3.
Connect the iBTS iPA 3 RJ-45 connector to the iPA COM 3 DB-9
connector with cable MCN 45-89330-M3.
Connect the iBTS S1 RX1 SMA Connector to the iPA RX1 Diversity SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS S1 TX/RX0 SMA Connector to the iPA TX/RX1 SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS S2 RX1 SMA Connector to the iPA RX2 Diversity SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS S2 TX/RX0 SMA Connector to the iPA TX/RX2 SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS S3 RX1 SMA Connector to the iPA RX3 Diversity SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS S3 TX/RX0 SMA Connector to the iPA TX/RX3 SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS 19.2 MHz SMA connector to iPA 19.2 MHz SMA
Connector with cable MCN 45-89331-M2.
3.4.2.2 Miscellaneous Connections for both iPA and BTS units
To connect the remainder connections:
For AC Rack mount version, just connect the AC cord to 110 or 220 V AC
supply.
For DC Rack Mount version, make sure the main rack breaker is off and the
BTS power switch is in the off position. Connect the –48v wire as indicated
on the rear of the unit marked “–“ or “–48v” and the positive (Bat. Rtn) wire
to the terminal marked “+” or Bat Return.
The BTS and iPA are now ready for configuration. Refer to iCell CDMA2000 1X Configuration
Guide.