Set Digital I/O Output Pulse Duration
This command sets the Digital I/O output pulse duration. Table 6-101 and Table 6-102
list the command and response data.
Output Pulse Duration
This field specifies the output pulse duration (digital out-
puts ON and OFF times). The digital outputs have a 50% duty cycle (Table 6-103).
03H Two-channel multiplexing (channels 0 and 1)
0CH Two-channel multiplexing (channels 2 and 3)
07H Three-channel multiplexing (channels 0, 1, and 2)
0FH Four-channel multiplexing (channels 0, 1, 2, and 3)
Table 6-100 RF Multiplexing Mode Values
Mode Value RF Multiplexing Mode
Table 6-101 Set Digital I/O Output Pulse Duration Command (000AH)
Set Digital I/O Output Pulse Duration Command Data Data Payload
Set Digital I/O Output Pulse Duration Command 000AH
Output Port Number: 0–3 for Port0–Port3 0XH
Output Pulse Duration 0XH
Table 6-102 Set Digital I/O Output Pulse Duration Response
Set Digital I/O Output Pulse Duration Response Data Data Payload
Set Digital I/O Output Pulse Duration Command 000AH
Table 6-103 Output Pulse Duration Values
Duration
Value
Pulse
Duration (ms)
00H 4
01H 8
02H 12
03H 16
04H 20