Get Digital I/O Minimum Presence True Period
This command gets the digital I/O minimum presence true period, which is the mini-
mum amount of time that the input must be valid. Table 6-110 and Table 6-111 list the
command and response data.
Minimum Presence True Period
This field specifies the minimum presence true
period (Table 6-112).
0CH 452
0DH 600
0EH 752
0FH Infinite (never tr ue)
Table 6-109 Minimum Presence True Period Values
True
Period
Value
True Period (ms)
Table 6-110 Get Digital I/O Minimum Presence True Period Command (000DH)
Get Digital I/O Minimum Presence True Period Command Data Data Payload
Get Digital I/O Minimum Presence True Period Command 000DH
Table 6-111 Get Digital I/O Minimum Presence True Period Response
Set Digital I/O Minimum Presence True Period Response Data Data Payload
Set Digital I/O Minimum Presence True Period Command 000DH
Minimum Presence True Period 0XH
Table 6-112 Minimum Presence True Period Values
True
Period
Value
True Period (ms)
00H 0 (always true)
01H 4
02H 8