User's Manual

Table Of Contents
Orion Reader System Guide
6-64 Use or disclosure of Proprietary Information contained on this sheet is subject to the restriction stated on the title page of this document.
Port Configuration This field specifies the digital port input/output configuration.
In Table 6-119, INPUT = 0 and OUTPUT = 1.
Note: RESET READER command required for changes to take effect.
Get Digital I/O Port Configuration
This command gets the digital I/O port configuration settings. Table 6-120 and Table
6-121 list the command and response data.
Table 6-119 Digital I/O Port Configuration Values
Configuration
Value
Digital Port 3 Digital Port 2 Digital Port 1 Digital Port 0
00H INPUT INPUT INPUT INPUT
01H INPUT INPUT INPUT OUTPUT
02H INPUT INPUT OUTPUT INPUT
03H INPUT INPUT OUTPUT OUTPUT
04H INPUT OUTPUT INPUT INPUT
05H INPUT OUTPUT INPUT OUTPUT
06H INPUT OUTPUT OUTPUT INPUT
07H INPUT OUTPUT OUTPUT OUTPUT
08H OUTPUT INPUT INPUT INPUT
09H OUTPUT INPUT INPUT OUTPUT
0AH OUTPUT INPUT OUTPUT INPUT
0BH OUTPUT INPUT OUTPUT OUTPUT
0CH OUTPUT OUTPUT INPUT INPUT
0DH OUTPUT OUTPUT INPUT OUTPUT
0EH OUTPUT OUTPUT OUTPUT INPUT
0FH OUTPUT OUTPUT OUTPUT OUTPUT
Table 6-120 Get Digital I/O Port Configuration Command (0011H)
Get Digital I/O Port Configuration Command Data Data Payload
Get Digital I/O Port Configuration Command 0011H