User's Manual

Table Of Contents
Orion Reader System Guide
6-90 Use or disclosure of Proprietary Information contained on this sheet is subject to the restriction stated on the title page of this document.
Protocol This field specifies the protocol for the Source Control command
Control
This field specifies the Uplink Source.
Set Frequency in MHz
Note: Set the reader to Stop Mode 0 before issuing the Set Frequency in MHz com-
mand.
Get Uplink Source Control Command 58H
Protocol Control XXH
Carriage Return 0DH
Table 6-167 Get Uplink Source Control Command (58H)
Get Uplink Source Control Command Data Data Payload
Table 6-168 Get Uplink Source Control Response
Get Uplink Source Control Response Data Data Payload
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Get Uplink Source Control Command 58H
Protocol Control XXH
Acknowledge 00H
Carriage Return 0DH
Protocol Definition
2IAG
3 CVISN
4 Title 21
8 ISO 18000-6C (EPC)
Control Definition
0 Uplink Source (source 2)
1 Uplink Source (source 1)