User's Manual

Table Of Contents
System Diagnostics and Preventive Maintenance
Use or disclosure of Proprietary Information contained on this sheet is subject to the restriction stated on the title page of this document. 9-21
RF Transceiver Interface Module Error Numbers
Table 9-12 contains the RF transceiver interface module (RFTIM) error numbers and
log entry descriptions.
GPS Self-Test Failed Event This error indicates that the self-test of the GPS module failed. 0003H
GPS Power On Failure Event This error indicates that the GPS module failed the power on
test.
0004H
GPS Auto Survey Failure
Ev
ent
This error indicates that the auto survey failed. 0005H
GPS Communication Link
Error Recovery Event
This event indicates that GPS Communication link, recovered. 0006H
GPS T-RAIM Alarm Set Error
Recovery Event
This event indicates that T-RAIM alarm cleared. 0007H
GPS Self-Test Failed
Recovery Event
This event indicates that self-test error cleared. 0008H
GPS Power-On Failure
Recovery Event
This event indicates that self-test error cleared. 0009H
GPS Auto Survey Failure
Recovery Event
This event indicates that the auto survey failure cleared. 000AH
Table 9-11 GPS Module Errors (0006H) (continued)
Table 9-12 RFTransceiver Interface Module Errors (0007H)
Log Entry Description
Error
Number
Reserved N/A 0000H
Buffer Management Create
Queue Error
This error indicates that the creation of a BM queue failed. This
error could prevent the Orion Reader’s ability to transact with
tags.
0001H
Memory Allocate Error This error indicates that the Memory allocation failed. This error
could prevent the Orion Reader’s ability to transact with tags.
0002H
System Queue ID Retrieve
Error
This error indicates that getting the system queue identification
failed. This error could prevent the Orion Reader’s ability to
transact with tags.
0003H
Serial SMC Open Error This error indicates that opening the serial SMC failed. This
error could prevent the Orion Reader’s ability to transact with
tags.
0004H
Connect Interrupt Handler
Error
This error indicates that connecting the interrupt handler failed.
This error could prevent the Orion Reader’s ability to transact
with tags.
0005H