13-MHz Disable Initialization
Error
This error indicates that there is a 13-MHz disable error. This
error could prevent the Orion Reader’s ability to transact with
tags.
0047H
RF Transceiver ADC Above
Maximum Error
This error indicates that the analog-to-digital converter (ADC)
in the control feedback loop has exceeded a maximum set
value. This error could prevent the Orion Reader’s ability to
transact with tags.
0201H
RF Transceiver ADC Below
Minimum Error
This error indicates that the ADC in the control feedback loop
has fallen below a minimum set value. This error could prevent
the Orion Reader’s ability to transact with tags.
0202H
RF Transceiver Attn DAC1
Above Maximum Error
This error indicates that the attenuation DAC for source 1 has
exceeded a maximum set value. This error could prevent the
Orion Reader’s ability to transact with tags.
0203H
RF Transceiver Attn DAC1
Below Minimum Error
This error indicates that the attenuation DAC for source 1 has
fallen below a minimum set value. This error could prevent the
Orion Reader’s ability to transact with tags.
0204H
RF Transceiver Attn DAC2
Above Maximum Error
This error indicates that the attenuation DAC for source 2 has
exceeded a maximum set value. This error could prevent the
Orion Reader’s ability to transact with tags.
0205H
RF Transceiver Attn DAC2
Below Minimum Error
This error indicates that the attenuation DAC for source 2 has
fallen below a minimum set value. This error could prevent the
Orion Reader’s ability to transact with tags.
0206H
RF Transceiver Depth-of-
Modulation (DOM) DAC
Above Maximum Error
This error indicates that the depth of modulation DAC has
exceeded a maximum set value. This error could prevent the
Orion Reader’s ability to transact with tags.
0207H
RF Transceiver DOM DAC
Below Minimum Error
This error indicates that the depth of modulation DAC has fallen
below a minimum set value. This error could prevent the Orion
Reader’s ability to transact with tags.
0208H
RF Transceiver Source1 PLL
Unlocked Error
This error indicates that the source 1 phase lock loop is
unlocked. This error could prevent the Orion Reader’s ability to
transact with tags.
0209H
RF Transceiver Source2 PLL
Unlocked Error
This error indicates that the source 2, phase lock loop is
unlocked. This error could prevent the Orion Reader’s ability to
transact with tags.
020AH
RF Transceiver 13-MHz
Control Error
This error indicates that there is a 13-MHz Control error. This
error could prevent the Orion Reader’s ability to transact with
tags.
020BH
RF Transceiver 5V DC Fault
Error
This error indicates that the 5VDC digital supply is above or
below the threshold. This error could prevent the Orion
Reader’s ability to transact with tags.
020CH
RF Transceiver Uncalibrated
Error
This error indicates that the Transceiver is uncalibrated. This
error could prevent the Orion Reader’s ability to transact with
tags.
020DH
Reserved N/A 020EH
Table 9-12 RFTransceiver Interface Module Errors (0007H) (continued)