User's Manual

Table Of Contents
Installing the Orion Reader
Use or disclosure of Proprietary Information contained on this sheet is subject to the restriction stated on the title page of this document. 3-5
Power Supply
The Orion Reader requires 19V DC to 30V DC or 19V AC to 27V AC RMS power
supply. Table 3-2 lists the external power connector specifications. Star Systems
offers a Class B transformer accessory kit (part number 76-6000-001) for sites where
either 110V AC or 220V AC is available. Accessory kit information is shown in Table
3-3.
Selecting a Power Supply
Power Return 7
Power Return 8
Sync- 3
Sync+ 4
I/O 1 1
I/O 1 Return 15
I/O 2 14
I/O 2 Return 13
I/O 3 12
I/O 3 Return 11
I/O 4 10
I/O 4 Return 9
Table 3-2 Orion Reader External Power Connector Specifications
Connector Type
DB15 Connector
Wire Gauge
12–22AWG
Note Installer must consider the wire resistance
versus overall length with respect to the Orion
Reader’s specified voltage range
Table 3-1 Power, Sync, and I/O Connector Pin Assignments (DB15)
Wire Pin No