Installing the Orion Reader
Use or disclosure of Proprietary Information contained on this sheet is subject to the restriction stated on the title page of this document. 3-7
Figure 3-2 Connecting Reader to Power Supply
Sync
At installations where cross-lane interference can occur and frequency management is
not sufficient to solve the problem, you may need to use Sync. By using the Sync
function in the Orion Readers, the readers operate only during interleaved time peri-
ods.
Note: In sites where installing Sync cabling is not an option, you can use the global
positioning system (GPS) timing alternative. See Appendix D, “Orion Reader
Options,” for more information.
The Orion Reader can support multiple lanes using Sync cabling. This connection pro-
vides a synchronization interface between readers where RF interference between
readers is reduced by multiplexing the RF reader transmission to independent time
slots. Allowing each reader or group of readers to operate at an allotted time elimi-
nates interference from readers in adjacent lanes.
Although you need to configure the readers to operate using Sync, the interface con-
nection for Sync, can be provided to all the readers in a plaza before or during installa-